نتایج جستجو برای: mri based polymer gel dosimetry

تعداد نتایج: 3180930  

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2004
Ulla Ramm Jussi Moog Belinda Spielberger Achim Bankamp Heinz-Dietrich Bottcher Gerhard Kraft

In this presentation BANG polymer-gel dosimetry using magnetic resonance imaging (MRI) is applied to densely ionizing radiation such as carbon ion beams. BANG polymer-gels were irradiated with monoenergetic 12C ions at an energy of 205 MeVu(-1). The irradiation of the gels with doses up to 100 Gy were performed at the radiotherapy facility of the GSI, Darmstadt, Germany. For comparison with spa...

2016
Hossein Khosravi Bijan Hashemi Faezeh Rahmani Ahmad Ebadi

PURPOSE In this work, gold nanoparticles (GNPs) were embedded in the MAGIC-f polymer gel irradiated with the 192Ir brachytherapy sources. MATERIAL AND METHODS At the first plexiglas phantom was made as the human pelvis. The GNPs were synthesized with 15 nm in diameter and 0.1 mM (0.0197 mg/ml) in concentration by using a chemical reduction method. Then, the MAGIC-f gel was synthesized. The fa...

Journal: :Journal of Physics: Conference Series 2009

H. Khalafi, M. Shahriari, M.H. Zahmatkesh, S. Bagheri, S.M. Abtahi, Sh. Akhlaghpoor,

parameters that have to be measured in gel dosimetry. However, the resolution in gel is strongly dependant on gel composition. Selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. Materials and Methods: MAGICA polymer gel dosimeters were manufactured and irradia...

B. Azadbakht, k. Hadad, M.H. Zahmatkesh, S. Bagheri,

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

D. Shahbazi-Gahrouei, M. Gholami, T. Allahverdi Pourfallah,

Background: The human body contains of different tissues and cavities with different physical and radiological properties. Most important among these are tissues and cavities that are radiologically different from water, including lungs, sinuses and bones. Gel dosimetry provides a unique feature to display dose distributions occurring in clinical radiation therapy in three dimensions. Materials...

Journal: :Journal of Physics: Conference Series 2009

Journal: :iranian journal of radiation research 0
s.m. abtahi shahid beheshti university, nuclear engineering faculty, tehran, iran m. shahriari shahid beheshti university, nuclear engineering faculty, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran h. khalafi nuclear science and technology research institute, tehran, iran sh. akhlaghpoor novin medical radiation institute, tehran, iran s. bagheri novin medical radiation institute, tehran, iran

parameters that have to be measured in gel dosimetry. however, the resolution in gel is strongly dependant on gel composition. selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. materials and methods: magica polymer gel dosimeters were manufactured and irradia...

Journal: :iranian journal of radiation research 0
n.n.a razak school of physics, university sains malaysia, 18000, pulau pinang, malaysia a.a. rahman 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia s. kandaiya 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia i.s. mustafa 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia a.a. mahmoud 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia n.z. yahaya school of distance education, university sains malaysia, 18000, pulau pinang, malaysia

background: an effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. materials and methods: the magat gel dosimeter formulations that used different compositions of methacrylic acid (maa) and gelatin were extensively investigated in the present study according to the r2–dose response and r2–dose sensitivity. the irradiation of magat gel was per...