نتایج جستجو برای: nickel titanium alloy

تعداد نتایج: 113808  

Journal: :The International journal of oral & maxillofacial implants 1999
B Bergendal S Palmqvist

The 5-year results from a multicenter study of implant-supported, laser-welded titanium frameworks are reported here as a complement to earlier reported 2-year results. Implant survival rates were satisfactory for patients with titanium frameworks and for a control group of patients with gold-alloy frameworks. At the 5-year review, more patients with titanium frameworks had lost implants than t...

2010
Masafumi Kikuchi

OBJECTIVES A nondestructive, rapid, and practical method of dental alloy sorting is desirable. In this study, the hypothesis to be tested is that dental alloys show significantly different and high thermoelectric power values, on the basis of which alloy sorting is possible. METHODS Six silver-colored commercial dental casting alloys are used in this study: two silver alloys, one gold-silver-...

2015
Yu-Tao Jian Yue Yang Tian Tian Clark Stanford Xin-Ping Zhang Ke Zhao Jie Zheng

Five types of porous Nickel-Titanium (NiTi) alloy samples of different porosities and pore sizes were fabricated. According to compressive and fracture strengths, three groups of porous NiTi alloy samples underwent further cytocompatibility experiments. Porous NiTi alloys exhibited a lower Young's modulus (2.0 GPa ~ 0.8 GPa). Both compressive strength (108.8 MPa ~ 56.2 MPa) and fracture strengt...

Journal: :Nihon Hotetsu Shika Gakkai zasshi 1989
Y Terada S Maeyama T Murakami N Sugimura F Iga R Hirayasu

The metals for porcelain fusing used in this study were gold alloys and nickel-chromium alloys. Chromatic characteristics were compared between samples of 0.1, 0.2 and 0.3 mm thickness. The dentin porcelain was fused on the opaque surface. Chromatic analyses were then carried out at each stage of 0.1 mm-incremental reductions of the dentin thickness starting from 0.5 mm. In conclusion, the meta...

Journal: :Journal of orthopaedic research : official publication of the Orthopaedic Research Society 2012
Ichiro Nakahara Masaki Takao Tomoyo Goto Chikara Ohtsuki Shigeru Hibino Nobuhiko Sugano

Despite the excellent osseointegration of carbon-fiber-reinforced polyetheretherketone (CFR/PEEK) with a surface hydroxyapatite (HA) coating, the bone-implant interfacial shear strength of HA-coated CFR/PEEK after osseointegration is unclear. We examined the interfacial shear strength of HA-coated CFR/PEEK implants after in vivo implantation in a rabbit femur-implant pull-out test model. HA coa...

2015
Tahsin Mansur Veljee C. S. Shruthi R. Poojya

UNLABELLED The purpose of this study was to evaluate and compare the effect of grit blasting, chemical treatment, and application of alloy primer combinations on the shear bond strength (SBS) of a self-cure resin cement to titanium surface. MATERIALS AND METHODS Fifty cast commercially pure titanium discs (9 mm × 2 mm) were divided into five groups (n = 10), which received the following surfa...

Journal: :American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics 2001
C Ciambotti P Ngan M Durkee K Kohli H Kim

A tandem-loop nickel titanium temperature-activated palatal expansion appliance was developed that produces light, continuous pressure on the midpalatal suture and requires little patient cooperation or laboratory work. The purpose of this study was to compare the effectiveness of the nickel titanium palatal expansion appliance with that of a rapid palatal expansion appliance. The study sample ...

2014
Maria Regina Guerra MONTEIRO Licinio Esmeraldo da SILVA Carlos Nelson ELIAS Oswaldo de Vasconcellos VILELLA

OBJECTIVE To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. MATERIAL AND METHODS Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric...

Journal: :Technologies (Basel) 2022

Friction stir welding (FSW) of titanium alloy was carried out using liquid cooling the FSW tool made heat-resistant nickel superalloy. Cooling superalloy performed by means circulating water inside tool. The joints were characterized microstructures and mechanical strength. strength higher than that base metal.

Journal: :Prosthetics and orthotics international 1992
M Takami K Fukui S Saitou I Sugiyama K Terayama

This paper describes new passive splints which have been developed using a shape memory alloy. The peculiar feature of the splints is that the way in which they change shape in use conforms to the stretching motion which it would be desirable to apply in certain conditions of deformity. The alloy consists of 55.66% by weight Nickel and 44.34% Titanium. The heat treatment of the alloy for memori...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید