نتایج جستجو برای: noise dose

تعداد نتایج: 502879  

2012
Yi-Wei Lee Ching-Ching Yang Greta S. P. Mok Tung-Hsin Wu

BACKGROUND The aims of this study were to investigate the image quality and radiation exposure of pediatric protocols for cardiac CT angiography (CTA) in infants under one year of age. METHODOLOGY/PRINCIPAL FINDINGS Cardiac CTA examinations were performed using an anthropomorphic phantom representing a 1-year-old child scanned with non-electrocardiogram-gated (NG), retrospectively electrocard...

Journal: :AJNR. American journal of neuroradiology 2013
B Schulz M Beeres B Bodelle R Bauer F Al-Butmeh A Thalhammer T J Vogl J M Kerl

BACKGROUND AND PURPOSE CT in low dose technique is the criterion standard imaging modality for evaluation of the paranasal sinus. Our aim was to evaluate the dose-reduction potential of a recently available sinogram-affirmed iterative reconstruction technique, regarding noise, image quality, and time duration when evaluating this region. MATERIALS AND METHODS CT was performed on a phantom hea...

Journal: :AJR. American journal of roentgenology 2009
Amy K Hara Robert G Paden Alvin C Silva Jennifer L Kujak Holly J Lawder William Pavlicek

OBJECTIVE The purpose of this study was to evaluate the image noise, low-contrast resolution, image quality, and spatial resolution of adaptive statistical iterative reconstruction in low-dose body CT. MATERIALS AND METHODS Adaptive statistical iterative reconstruction was used to scan the American College of Radiology phantom at the American College of Radiology reference value and at one-ha...

Journal: :iranian journal of radiation research 0
m. mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia e. bezak

abstractbackground: although electronic portal imaging devices (epids) have originally developed for positioning verification, they can also be used for dosimetric purposes. in the current work, the dose response of minimum detectable thickness of a scanning liquid filled ion chamber epid, slic-epid, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was als...

2008
Paul McDonald Dermot Geraghty Ivor Humphreys Stephen Farrell

One of the problems associated with assessing the impact of noise pollution is the relative nature of sound measurement. Apart from the fact that sound levels are measured on a logarithmic scale, noise intrusion can often be highly relative to the listener’s surroundings. The impact of noise events is commonly compared with the background or ambient noise level and so is not solely dependent on...

2016
Dawid Mozejko Hilde Kjernlie Andersen Marius Pedersen Dag Waaler Anne Catrine Trægde Martinsen

The aim of this study was to compare image noise properties of GE Discovery HD 750 and Toshiba Aquilion ONE. The uniformity section of a Catphan 600 image quality assurance phantom was scanned with both scanners, at different dose levels and with extension rings simulating patients of different sizes. 36 datasets were obtained and analyzed in terms of noise power spectrum. All the results prove...

Journal: :Radiology 2013
François Pontana Julien Pagniez Alain Duhamel Thomas Flohr Jean-Baptiste Faivre Colm Murphy Jacques Remy Martine Remy-Jardin

PURPOSE To evaluate image quality of low-voltage chest computed tomographic (CT) angiography with raw data-based iterative reconstruction (sonogram-affirmed iterative reconstruction) in comparison with image quality of standard-dose standard-voltage filtered back projection (FBP) CT. MATERIALS AND METHODS This prospective study was approved by the institutional review board, and the informed ...

2012
D. Yantek J. Peterson E. Ferro

Among underground coal miners, hearing loss remains one of the most common occupational illnesses. To address this problem, the U.S. National Institute for Occupational Safety and Health Office of Mine Safety and Health Research (NIOSH OMSHR) conducts research to reduce the noise emission of underground coal mining equipment, an example of which is the roof bolting machine. Field studies show t...

2016
Davood Karimi Pierre Deman Rabab Kreidieh Ward Nancy Ford

BACKGROUND From the viewpoint of the patients' health, reducing the radiation dose in computed tomography (CT) is highly desirable. However, projection measurements acquired under low-dose conditions will contain much noise. Therefore, reconstruction of high-quality images from low-dose scans requires effective denoising of the projection measurements. METHODS We propose a denoising algorithm...

2013
Hyun Joo Shin Yong Eun Chung Young Han Lee Jin-Young Choi Mi-Suk Park Myeong-Jin Kim Ki Whang Kim

OBJECTIVE To evaluate the feasibility of sinogram-affirmed iterative reconstruction (SAFIRE) and automated kV modulation (CARE kV) in reducing radiation dose without increasing image noise for abdominal CT examination. MATERIALS AND METHODS This retrospective study included 77 patients who received CT imaging with an application of CARE kV with or without SAFIRE and who had comparable previou...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید