نتایج جستجو برای: otoacoustic emissions spontaneous

تعداد نتایج: 178936  

Journal: :Otolaryngologia polska = The Polish otolaryngology 2007
Grazyna Lisowska Grzegorz Namysłowski Bogusława Orecka Maciej Misiołek Wojciech Scierski Eugeniusz Czecior

INTRODUCTION The objective of this study was to measure age-related changes of otoacoustic emissions level in subjects with normal hearing in tonal audiometry. MATERIAL AND METHODS Click evoked otoacoustic emissions (CEOAEs) and distortion-product otoacoustic emissions (DPOAEs) were recorded in 146 (n = 292 ears) subjects. Otoacoustic emissions were recorded in response to nonlinear clicks an...

Journal: :The journal of international advanced otology 2017
Prashanth Prabhu Gowtham Varma Kristi Kaveri Dutta Prajwal Kumar Swati Goyal

OBJECTIVE In this study, an attempt was made to determine the effect of smoking on ultra-high-frequency auditory sensitivity. The study also attempted to determine the relationship between the nature of smoking and ultra-high-frequency otoacoustic emissions (OAEs) and thresholds. MATERIALS AND METHODS The study sample included 25 smokers and 25 non-smokers. A detailed history regarding their ...

Journal: :The international tinnitus journal 2012
Marlene Escher Boger André Luiz Lopes Sampaio Carlos Augusto Costa Pires de Oliveira

INTRODUCTION The otoacoustic emission test is useful in monitoring hearing changes not yet detectable in pure-tone audiometry, as well as in monitoring cochlear damage caused by exposure to noise. OBJECTIVE To evaluate distortion product otoacoustic emissions in normal-hearing workers exposed to different occupational noise doses. MATERIALS AND METHOD This is a cohort prospective study perf...

2016
Prawin Kumar Vibhu Grover Sam Publius A Himanshu Kumar Sanju Sachchidanand Sinha

Objective Contralateral suppression of oto acoustic emission (OAE) is referred as activation of efferent system. Previous literature mentioned about the importance of contralateral suppression of OAEs as a tool to assess efferent system in different groups of population. There is dearth of literature to explore the efferent system function in experienced musicians exposed to rock music using TE...

Journal: :Pro-fono : revista de atualizacao cientifica 2010
Patricia Pinheiro de Almeida Seisse Gabriela Gandolfi Sanches Renata Mota Mamede Carvallo

BACKGROUND Distortion product otoacoustic emission measures (DPOAE) verifies, among other characteristics, the emergence and growth rate of the DPOAE response according to sound stimulus intensity (growth curve). AIM To estimate the DPOAE threshold in neonates according to the DPOAE growth curve at 2 kHz and 4 kHz, with stimulus presentation ranging between 35 and 70 dB SPL. METHOD Particip...

Journal: :Brazilian journal of otorhinolaryngology 2012
Daila Urnau Tania Maria Tochetto

UNLABELLED The association between tinnitus and hyperacusis is common according to the literature. AIM To verify the occurrence and the suppression effect of transient otoacoustic emissions (TEOAE), the existence of association between tinnitus degrees and hyperacusis degrees, and between the suppressive effect of TEOAE and laterality, tinnitus and hyperacusis degrees in normal hearing adults...

Journal: :Journal of the American Academy of Audiology 2004
Carlie Driscoll Joseph Kei Jenny Shyu Natasha Fukai

Otoacoustic emissions are frequently acquired from patients in a variety of body positions aside from the standard, seated orientation. Yet little knowledge is available regarding whether these deviations will produce nonpathological changes to the clinical results obtained. The present study aimed to describe the effects of body position on the distortion-product otoacoustic emissions of 60 no...

Journal: :The Journal of the Acoustical Society of America 1996
D M Mills E W Rubel

The development of the cochlear amplifier was examined in gerbils aged 14 days after birth (dab) to adult, for stimulus frequencies from 1 to 48 kHz. Distortion product otoacoustic emissions (DPOAEs) were employed to determine the characteristics of active emissions associated with cochlear amplifier operation. DPOAEs were also used to determine the characteristics of "passive" emissions remain...

Journal: :Brazilian journal of otorhinolaryngology 2011
Raquel Mari Onoda Marisa Frasson de Azevedo Amélia Miyashiro Nunes dos Santos

UNLABELLED To check the rate of failure, hearing loss and its association with demographic variables and risk indicators for hearing loss in newborns submitted to the Newborn Hearing Screening in a secondary hospital. MATERIALS AND METHODS Cross-sectional and retrospective study, involving 1,570 newborns submitted to the different stages of the Newborn Hearing Screening Program. Initially, we...

Journal: :Hearing research 1994
D M Mills E W Rubel

Cochlear function was monitored in adult gerbils using distortion product otoacoustic emissions (DPOAE) during intraperitoneal injection of furosemide. All stimulus parameters were varied independently over a wide range, the stimulus frequencies f1 and f2 from 1 to 16 kHz, and the stimulus levels L1 and L2 from 20 to 80 dB SPL. The observed emissions at 2f1-f2 and 3f1-2f2 could be considered to...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید