نتایج جستجو برای: particle size distribution curve
تعداد نتایج: 1344075 فیلتر نتایج به سال:
LiF powder having particle size of 50-200 µm doped with Mg, Cu and P impurities was produced using melting method. The whole construction process was conducted in a nitrogen atmosphere. The effect of Cu impurity on the thermoluminescence glow curve was investigated and the appropriate amount of Cu was determined. The TL properties of the fabricated phosphor was compared to commercial LiF:Mg,Cu,...
Determination of particle size is one of the major needs in the industry and biotechnology. Dynamic light scattering (DLS) is a widely used technique for determining size distribution of spherical particle in nanometer and submicron size range. In this method, there are different algorithms for determining the size and size distribution of particles, which are selected according to the required...
During the summer of 2012, we used laser diffractometry to investigate the temporal and vertical variability of the particle size spectrum (1.25–100 mm in equivalent diameter) in the euphotic zone of the North Pacific Subtropical Gyre. Particles measured with this optical method accounted for;40% of the particulate carbon stocks (<202 mm) in the upper euphotic zone (25–75 m), as estimated using...
The temperature dependence of the effective magnetic anisotropy constant, K(T), of MnFe2O4 nanoparticles is obtained based on superconducting quantum interference device magnetometry measurements. The variation of the blocking temperature, TB, as a function of particle radius, r, is first determined by associating the particle size distribution and the anisotropy energy barrier distribution ded...
in our previous work, the effect of use of a water soluble cdi/nhs system as nontoxic cross-linking agent on fabrication of gelatin nanoparticles was investigated. in this research, the effect of variation in some synthetic parameters of gelatin nanoparticles cross-linked by cdi/nhs system such as type of gelatin and formulation of cross- linking agent on their size and distribution was examine...
a mixture of sodium lauryl sulfate (sls) as ionic emulsifer and stearyl alcohol as non-ionic emulsifer was employed in a vinyl chloride emulsion polymerization reaction to study the infuence of various interactive parameters involved in the reaction system. it was found that the particle size was dependent on the amount and type of emulsifer. the average particle size of polyv...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید