نتایج جستجو برای: peak detector
تعداد نتایج: 198135 فیلتر نتایج به سال:
A common way of speeding up powder diffraction measurements is the use of one- or two-dimensional detectors. This usually goes hand in hand with worse resolution and asymmetric peak profiles. In this work the influence of a straight linear detector on the resolution function in the Bragg-Brentano focusing geometry is discussed. Because of the straight nature of most modern detectors geometrical...
The FT (peak bolometric photon flux) vs. Ep (peak energy) plane is a powerful tool to compare the burst populations detected by different detectors. Detector sensitivity curves in this plane demonstrate which burst populations the detectors will detect. For example, future CZT-based detectors will show the largest increase in sensitivity for soft bursts, and will be particularly wellsuited to s...
abstract background: coherent scattering leads to diffraction effects and especially constructive interferences. theseinterferences carry some information about the molecular structure of the tissue. as breast cancer isthe most widespread cancer in women, this project evaluated the application of small anglex-ray scattering (saxs) for differentiation between normal and cancerous breast tissues....
Synchrotron X-rays on the Swiss Norwegian Beamline and BM28 (XMaS) at the ESRF have been used to record the diffraction response of the PMN-PT relaxor piezoelectric 67% Pb(Mg1/3Nb2/3)O3-33% PbTiO3 as a function of externally applied electric field. A DC field in the range 0-18 kV cm-1 was applied along the [001] pseudo-cubic direction using a specially designed sample cell for in situ single-cr...
در این پایان نامه یک مدار حلقه قفل تاخیر با دو لبه سنکرون شونده با سرعت قفل بالا، محدوده فرکانسی وسیع و ولتاژ تغذیه پایین شرح داده شده است که اغلب در پروسه های هم تراز کننده ساعت مورد استفاده قرار می گیرد. در این پروژه، دو معماری تقریبا مشابه پیشنهاد شده است. نتایج شبیه سازی با برنامه hspice بر پایه تکنولوژی های cmos ?m18/0 و ?m13/0 می باشد. معماری پیشنهادی اولیه، حلقه قفل تاخیر با دو لبه سنکر...
A clock and data recovery (CDR) circuit using a new halfrate wide-range phase detection technique has been developed. Unlike the conventional three-state phase detectors, the proposed detector is applicable to the Non-Return-to-Zero (NRZ) data stream and also has low jitter and wide capture range characteristics. The CDR circuit was implemented in a 0.35-μm N-well CMOS technique. Experimental r...
This paper presents a high dynamic range (DR), power efficient VCO-based continuous time ΔΣ modulator (CTDSM). It introduces a simple, robust and low power fully digital phase extended quantizer (PEQ) that doubles the VCO quantizer resolution compared to conventional XOR-based phase detector with minimum overhead. A tri-level resistor DAC is also introduced as complementary to the new quantizer...
A wide variety of applications require a hard Xray or gamma ray detector which combine both good spatial resolution and energy resolution. Double-sided solid-state strip detectors provide this capability. We report on the development of CMOS electronics designed for photon detection with strip detectors. These electronics include a low noise preamplifier, semi-gaussian shaping amplifier, discri...
The use of germanium detectors for the identification and quantification of radionuclides in unknown and non-standard counting geometries has increased in the recent past with the need to clean up and verify sites used for radionuclide processing, smuggling detection and other purposes. The calculation of the amount of radionuclide present requires a knowledge of the efficiency of the detector ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید