نتایج جستجو برای: phantom scatter factor

تعداد نتایج: 870740  

Journal: :Applied optics 1995
J C Hebden D J Hall M Firbank D T Delpy

A solid plastic phantom has been developed with optical properties that closely match those of human breast tissue at near-IR wavelengths. The phantom is a 54-mm-thick slab containing four small cylinders of contrasting scatter and absorption. A detailed description of the phantom is followed by an account of an attempt to image the phantom by a time-resolved imaging technique. Images generated...

Journal: :Medical physics 2015
G J Bootsma F Verhaegen D A Jaffray

PURPOSE X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). METHO...

Journal: :Physics in medicine and biology 2009
Cristian C Constantinescu Jogeshwar Mukherjee

We evaluated the performance of an Inveon preclinical PET scanner (Siemens Medical Solutions), the latest MicroPET system. Spatial resolution was measured with a glass capillary tube (0.26 mm inside diameter, 0.29 mm wall thickness) filled with (18)F solution. Transaxial and axial resolutions were measured with the source placed parallel and perpendicular to the axis of the scanner. The sensiti...

2012
Alain Seret Daniel Nguyen Claire Bernard

BACKGROUND Four state-of-the-art single-photon emission computed tomography-computed tomography (SPECT-CT) systems, namely Philips Brightview, General Electric Discovery NM/CT 670 and Infinia Hawkeye 4, and Siemens Symbia T6, were investigated in terms of accuracy of attenuation and scatter correction, contrast recovery for small hot and cold structures, and quantitative capabilities when using...

Journal: :Annals of nuclear medicine 2003
Hideki Kobayashi Mitsuru Momose Shinichi Kanaya Chisato Kondo Kiyoko Kusakabe Norio Mitsuhashi

UNLABELLED Heart to mediastinum count ratio (H/M) has been commonly utilized as an indicator of myocardial I-123 MIBG uptake. However, normal ranges of H/M were markedly different among various gamma camera systems. The purpose of this study was to clarify whether scatter correction by two-window method standardizes H/M among various gamma camera systems. METHODS Scatter uncorrected and corre...

Journal: :Medical physics 2009
Lei Zhu Yaoqin Xie Jing Wang Lei Xing

Cone-beam CT (CBCT) is being increasingly used in modern radiation therapy for patient setup and adaptive replanning. However, due to the large volume of x-ray illumination, scatter becomes a rather serious problem and is considered as one of the fundamental limitations of CBCT image quality. Many scatter correction algorithms have been proposed in literature, while a standard practical solutio...

Journal: :Radiology 2005
Ehsan Samei Joseph Y Lo Terry T Yoshizumi Jonathan L Jesneck James T Dobbins Carey E Floyd H Page McAdams Carl E Ravin

PURPOSE To evaluate the scatter, dose, and effective detective quantum efficiency (DQE) performance of a slot-scan digital chest radiography system compared with that of a full-field digital radiography system. MATERIALS AND METHODS Scatter fraction of a slot-scan system was measured for an anthropomorphic and a geometric phantom by using a posterior beam-stop technique at 117 and 140 kVp. Me...

Journal: :Medical physics 2016
D Branco P Taylor S Frank H Li X Zhang H Mehrens M Guindani D Followill

PURPOSE To design a Head and Neck (H&N) anthropomorphic QA phantom that the Imaging and Radiation Oncology Core Houston (IROC-H) can use to verify the quality of intensity modulated proton therapy (IMPT) H&N treatments for institutions participating in NCI clinical trials. METHODS The phantom was created to serve as a remote auditing tool for IROC-H to evaluate an institution's IMPT planning ...

Fateme Shahedi, Hossein Akbari Mahdi Jamali Mahdi Mommen nezhad shahrokh Nasseri,

Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...

Ahmad Bitarafan Rajabi Bijan Hashemi Malayeri Fereidoon Rastgoo Hassan Firoozabadi Hossein Rajabi, Nahid Yaghoobi Nasrollah Jabbari

Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید