نتایج جستجو برای: potentiometric sensor
تعداد نتایج: 191184 فیلتر نتایج به سال:
In this study, a potentiometric uric acid biosensor was fabricated by immobilization of uricase onto zinc oxide (ZnO) nanowires. Zinc oxide nanowires with 80-150 nm in diameter and 900 nm to 1.5 μm in lengths were grown on the surface of a gold coated flexible plastic substrate. Uricase was electrostatically immobilized on the surface of well aligned ZnO nanowires resulting in a sensitive, sele...
a carbon paste electrode modified with cobalt (ii) phthalocyanine (copc) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. the potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 m (?1- 1800 µg ml ) with a nernstian slope of 56 mv at ph 7. the limit of detection was 0.2 µg ml ascor...
in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...
Using Zn(2+)-BPMP or Cu(2+)-BPMP as a receptor and o-mercaptophenol as an indicator, potentiometric sensing of aqueous phosphate by competition assays was achieved. With attractive features of portability, low cost and resistance to interference from turbidity and color, this sensor was successfully used for phosphate detection in biological and water samples.
We present a new type of chemical transducer, the co~orn~~c sensor, This sensor is in fact an integrated sensor-actuator system that is able to measure the concentration of acids and bases by means of a coulometric titration. An ISFET is used as the sensor to monitor the pH changes induced by the actuator, which is a gold electrode that fits closely around the ISFET’s gate area. Coubmetry is an...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید