Journal: :Journal of the Korea Concrete Institute 2012

Hooshang Dabbagh, Muhammad Abbassi

Fiber reinforced Polymers (FRP) have widely used for the purposes of enhances strength and ductility of concrete columns. Proper design of such hybrid columns, however, requires a better recognition of the behavior of concrete columns confined with FRP. In this paper, the influence of FRP thickness, concrete compressive strength, and column size on the performance of eccentrically loaded reacti...

Journal: :Journal of Structural and Construction Engineering (Transactions of AIJ) 2002

2010
Yaping Peng Guang Dong

Based on the experimental study for seismic performance of FRP reinforced concrete beam-column joints, two-storey two-span plane frames were taken for examples, in which the static elastoplastic analysis (the pushover method) was carried on the joints of the FRP strengthened concrete frames, and then the comparative analysis was made on seismic performance of RFP strengthened frame structure th...

2014
Mohamed H. Mahmoud Hamdy M. Afefy Nesreen M. Kassem Tarek M. Fawzy

This paper presents an experimental study for the structural performance of reinforced concrete (RC) exterior beam-column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP). The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered de...

2015
Ahmed Gouda Mahmoud Reda Taha

A finite element model (FEM) was constructed using specialized three-dimensional (3D) software to investigate the punching shear behavior of interior slab-column connections subjected to a moment-to-shear ratio of 0.15 m. The FEM was then verified against the experimental results of full-scale interior slab-column connections reinforced with glass fiber reinforcement polymer (GFRP) bars previou...

2017
Muhammad N. S Hadi

The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection is a T connection representing a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised st...

2012
T. Jiang

An important application of fiber-reinforced polymer (FRP) composites is to provide confinement to reinforced concrete (RC) columns to enhance their loadcarrying capacity. However, this application is generally restricted to short columns as existing design guidelines do not contain provisions for the design of FRP jackets for slender columns. This situation has been due to both the scarcity of...