نتایج جستجو برای: resistivity

تعداد نتایج: 11971  

2003

Pertamina has conducted geothermal exploration in Sumatra showing that the depths to the top of most of the geothermal reservoirs are about 1000-2000 meters. Previous geophysical exploration work by Pertamina emphasized the use of DC-resistivity methods such as the Schlumberger method. However, these techmques can typically only penetrate to a depth of less than 1000 meters and are too shallow ...

2000
R. Arnaldi A. Baldit V. Barret N. Bastid G. Blanchard E. Chiavassa P. Cortese P. Crochet G. Dellacasa N. De Marco P. Dupieux B. Espagnon J. Fargeix A. Ferretti M. Gallio L. Lamoine L. Luquin F. Manso V. Metivier A. Musso C. Oppedisano A. Piccotti A. Rahmani L. Royer O. Roig E. Scalas E. Scomparin E. Vercellin

The use of phenolic or melaminic bakelite as RPC electrodes is widespread. The electrode resistivity is an important parameter for the RPC performance. As recent studies pointed out, the bakelite resistivity changes with temperature and is in#uenced by humidity. In order to gain a quantitative understanding on the in#uence of temperature and humidity on RPC electrodes, we assembled an apparatus...

2014
Youcef Zeroukhi Ewa Napieralska-Juszczak Guillaume Vega Krzysztof Komeza Fabrice Morganti Slawomir Wiak

During the manufacturing process multi-strand conductors are subject to compressive force and rotation moments. The current distribution in the multi-strand conductors is not uniform and is controlled by the transverse resistivity. This is mainly determined by the contact resistance at the strand crossovers and inter-strand contact resistance. The surface layer properties, and in particular the...

2017
Honglong Ning Yicong Zhou Zhiqiang Fang Rihui Yao Ruiqiang Tao Jianqiu Chen Wei Cai Zhennan Zhu Caigui Yang Jinglin Wei Lei Wang Junbiao Peng

Inkjet-printed silver gate electrode with low electrical resistivity was fabricated by UV curing method. By adjusting the UV curing time and the distance between the samples and UV lamp, the effects of UV curing conditions on the electrical resistivity of the silver films were studied, and the lowest electrical resistivity of 6.69 × 10-8 Ω·m was obtained. Besides, the UV-cured silver films have...

Journal: :IEICE Transactions 2009
Hironari Chikaoka Yoichi Takakuwa Kenji Shiojima Masaaki Kuzuhara

We have evaluated the tunneling contact resistivity based on numerical calculation of tunneling current density across an AlGaN barrier layer in non-polar AlGaN/GaN heterostructures. In order to reduce the tunneling contact resistivity, we have introduced an n-AlXGa1−XN layer between an n-GaN cap layer and an i-AlGaN barrier layer. The tunneling contact resistivity has been optimized by varying...

2007
D. Passeri G. M. Bilei

Low-resistivity materials have been proposed for the fabrication of radiation-hard solid-state particle detectors. A complete analysis of low-resistivity detector performance, including the estimate of charge collection efficiency, has been carried out by using a numerical device simulator, and compared with results expected from conventional, high-resistivity devices. By exploiting the feature...

Journal: :The Journal of General Physiology 1975
D O Carpenter M M Hovey A F Bak

The specific resistivity of the axoplasm of giant axons of squid and Myxicola was measured utilizing a single metal microelectrode subjected to alternating current in a circuit in which the voltage output varies with the conductivity of the thin layer of fluid at the exposed electrode tip. The average specific resistivity of stellar axons of Loligo pealei was 31 omegacm (1.55 times seawater [X ...

2017
Innocent C. Ezenwa Richard A. Secco Wenjun Yong Monica Pozzo

The electrical resistivity of high purity Cu has been investigated by both experiments and first principle calculations at pressures up to 5 GPa and at temperatures in the liquid phase up to 1730 K. The resistivity decreases with P and increases with T and our data are in very good agreement in relation to 1 atm data. Our melting temperature data agree with other experimental studies. We show t...

2010
M. Ramya S. Ganesan

Cu2S thin films have been prepared by vacuum evaporation method from CuS powder. Cu2S was deposited onto precleaned flat glass substrates coated under a pressure of 10 torr at an evaporation rate of 3Å /sec. The resistivity of the vacuum evaporated Cu2S thin films was measured in the temperature range 303K-453K and was found between 10 to 10 ohm cm. This low resistivity is due to degenerate nat...

Journal: :American journal of physiology. Heart and circulatory physiology 2006
Maricela Reyes Mark E Steinhelper Jorge A Alvarez Daniel Escobedo John Pearce Jonathan W Valvano Brad H Pollock Chia-Ling Wei Anil Kottam David Altman Steven Bailey Sharon Thomsen Shuko Lee James T Colston Jung Hwan Oh Gregory L Freeman Marc D Feldman

Conductance measurements for generation of an instantaneous left ventricular (LV) volume signal in the mouse are limited, because the volume signal is a combination of blood and LV muscle, and only the blood signal is desired. We have developed a conductance system that operates at two simultaneous frequencies to identify and remove the myocardial contribution to the instantaneous volume signal...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید