نتایج جستجو برای: slab head phantom

تعداد نتایج: 193829  

Journal: :iranian journal of medical physics 0
hamid reza sadoughi m.sc. student of medical physics, medical physics dept., tehran university of medical sciences, tehran, iran mahmood allahverdi associate professor, medical physics dept., tehran university of medical sciences, and radiotherapy physics department of cancer institute, tehran, iran hasan nedaei assistant professor, radiotherapy physics dept., cancer institute, tehran, iran ramin jaberi radiotherapy physicist, radiotherapy physics dept., cancer institute, tehran, iran mahbod esfahani radiotherapy physicist, radiotherapy physics dept., cancer institute, tehran, iran alireza shirazi associated professor, medical physics dept., tehran university of medical sciences, tehran, iran

introduction: multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. in this work, we investigated mr-based magic gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. materials and methods: a heterogeneous slab phantom including bones was made....

Journal: :iranian journal of science and technology (sciences) 2015
m. mahdavi

computed tomographyrepresents about 10% of all diagnostic radiology procedures, but it isresponsible for almost 50% - 60% of exposure from diagnostic procedures. inhead ct, other critical organs such as eye lenses and thyroids are in theradiation field. therefore, dose assessment in these organs is very important.the aim of this study is to estimate the absorbed dose in critical organs ofpatien...

Journal: :Spektra: jurnal fisika dan aplikasinya 2022

The water phantom is used for LINAC calibration to measure absorbed dose radiation. Practically, it requires a long preparation time and considered less efficient. To increase efficiency, the medical physics team in hospital uses slab as tool. Consequently, correction factor crucial define equivalence of doses resulted from phantom. measurement was performed according IAEA TRS-398 dosimetry pro...

Journal: :Japanese Journal of Radiological Technology 1996

Journal: :Optics letters 2004
Jeremy C Hebden Jorge J García Guerrero Victor Chernomordik Amir H Gandjbakhche

A model has been developed based on random walk theory that allows the diffusion of light along a principal axis to differ from that in orthogonal directions. We present expressions that describe the time-resolved intensity measured across a slab and on the surface of a semi-infinite medium for a principal axis oriented parallel or perpendicular to the surface. The model of time-resolved transm...

Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...

Journal: :iranian journal of radiation research 0
a. vahidian kamyad department of mathematic, ferdowsi university, mashad, iran m.h. noori eskandari department of mathematic, ferdowsi university, mashad, iran m. naji midani department of medical physics, mashad university for medical sciences, mashad, iran m. hajizadeh saffar department of medical physics, mashad university for medical sciences, mashad, iran

background: photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of spect images and results to errors in accuracy of quantitative measurements. this can be corrected via different physical or mathematical approaches. as the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘piece wise line...

Journal: :The British journal of radiology 1997
M Stasi V Casanova Borca C Fiorino

An important step in the verification of the reliability of portal films as in vivo dosemeters is the evaluation of the agreement between exit dose profiles and optical density profiles measured on the portal film. To test the possibilities of a conventional portal film system in 60Co beams suitable for head and neck irradiation, we verified the agreement between relative exit doses (measured b...

2015
Harley H. L. Chan Jeffrey H. Siewerdsen Allan Vescan Michael J. Daly Eitan Prisman Jonathan C. Irish David Warburton

The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material parana...

2003
R. Md. Yusof J. C. Hebden A. Gibson N. Everdell T. Austin J. H. Meek S. R. Arridge J. S. Wyatt D. T. Delpy

Optical tomography is being developed at UCL as a tool for understanding the mechanisms of haemorrhagic and hypoxic-ischaemic brain injury and assessing the effectiveness of novel neural rescue therapies in the newborn infant. Our 32-channel time-resolved optical imaging system measures photon flight times between multiple pairs of points on the surface of the head, and images sensitive to loca...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید