نتایج جستجو برای: temperature measurement

تعداد نتایج: 870426  

2016
Yi Liu Jun Zhang

Surface temperature is an important parameter in clinical diagnosis, equipment state control, and environmental monitoring fields. The Fiber Bragg Grating (FBG) temperature sensor possesses numerous significant advantages over conventional electrical sensors, thus it is an ideal choice to achieve high-accuracy surface temperature measurements. However, the effects of the ambient temperature and...

2015
Giampiero de Cesare Augusto Nascetti Domenico Caputo

In this work, we propose a multi-parametric sensor able to measure both temperature and radiation intensity, suitable to increase the level of integration and miniaturization in Lab-on-Chip applications. The device is based on amorphous silicon p-doped/intrinsic/n-doped thin film junction. The device is first characterized as radiation and temperature sensor independently. We found a maximum va...

Journal: :Optics express 2011
D V Strekalov R J Thompson L M Baumgartel I S Grudinin N Yu

Temperature measurement with nano-Kelvin resolution is demonstrated at room temperature, based on the thermal dependence of an optical crystal anisotropy in a high quality whispering gallery mode resonator. As the resonator's TE and TM modes frequencies have different temperature coefficients, their differential shift provides a sensitive measurement of the temperature variation, which is used ...

احمدنیا, حسن, خواجه‌دلوئی, محمد, قنبری‌زاده, سعیدرضا, مجاهدی, محمدجواد,

Background and Aim: Patients who undergo kidney transplantation take immunosuppressive drugs that make them susceptible to different infections. Since fever is one of prominent symptoms of infection, continuous measurement of temperature is very important. The goal of this research was to find if there is any significant difference between intravesical, oral, rectal and axillary temperatures. M...

Journal: :Journal of physics 2023

Abstract Due to the measuring distance, there are variable degrees of temperature measurement differences when infrared monitoring technology is employed take a building envelope, which can directly lead distortion in detection envelope temperature. In order address this issue, data from 20 sets different locations were acquired through field testing analyzing and interior latex-painted wall. B...

Journal: :مهندسی بیوسیستم ایران 0
پدرام شعاع دانشجوی کارشناسی ارشد گروه مهندسی مکانیک ماشین‏های کشاورزی، دانشکدۀ کشاورزی، دانشگاه صنعتی اصفهان عباس همت استاد گروه مهندسی مکانیک ماشین‏های کشاورزی، دانشکدۀ کشاورزی، دانشگاه صنعتی اصفهان رسول امیرفتاحی دانشیار دانشکدۀ مهندسی برق و کامپیوتر، دانشگاه صنعتی اصفهان مهدی قیصری استادیار گروه مهندسی آب، دانشکدۀ کشاورزی، دانشگاه صنعتی اصفهان

in order to decrease water consumption in agricultural sector, deficit irrigation has been suggested. for preventing a heavy loss in crop yield, management of water stress is essential. common methods for measuring plant water stress such as stomatal conductance are time-consuming and require specialized labor and a large number of measurement. temperature of leaf or canopy surface can be an in...

2003
JOON W. CHOI FRANCESC PETERS

Two different psychrophilic types of the heterotrophic nanoflagellate Paraphysomonas imperforata were isolated from Newfoundland coastal waters and the Arctic Ocean. When fed bacteria without food limitation, both isolates were able to grow at temperatures from -1.8 to 20°C, with maximum growth rates of 3.28 day-' at 15°C and 2.28 day-l at 12.3°C for the Newfoundland and the Arctic isolates, re...

2008
Jeonggon Harrison Kim

Recently the author of this article proposed a new signal processing algorithm for an all fiber white light interferometer. In this article, an all fiber white light interferometric absolute temperature measurement system is presented using the previously proposed signal processing algorithm. Stability and absolute temperature measurement were demonstrated. These two tests demonstrated the feas...

2014
Robert Frischer Marek Penhaker Ondrej Krejcar Marian Kacerovsky Ali Selamat

Precise temperature measurement is essential in a wide range of applications in the medical environment, however the regarding the problem of temperature measurement inside a simple incubator, neither a simple nor a low cost solution have been proposed yet. Given that standard temperature sensors don't satisfy the necessary expectations, the problem is not measuring temperature, but rather achi...

2014
Karel Allegaert Kristina Casteels Ilse van Gorp Guy Bogaert

INTRODUCTION Body temperature measurement in children is of clinical relevance. Although rectal measurement is the gold standard, less invasive tools have become available. We aimed to describe the accuracy of tympanic, infrared skin, or temporal artery scan thermometers compared with rectal measurement to reflect core temperature. METHODS Rectal (Filac 3000; Covidien, Mechelen, Belgium), tym...