نتایج جستجو برای: ternary mixtures
تعداد نتایج: 64666 فیلتر نتایج به سال:
Mechanical alloying of binary and ternary elemental powder mixtures with the nominal compositions of Mg2Ni and Mg(2-x)MnxNi (x= 0, 0.05, 0.10 and 0.15 at. %) were carried out in a planetary ball mill for various milling times of 5, 10, 15, 20, 30 and 60 h. X-ray diffraction and field emission scanning and transmission electron microscopy were used for the characterization of the milled products...
A recently improved ionic liquid force field was used to compute the viscosity for binary and ternary mixtures of 1-ethyl-3-methylimidazolium chloride ([emim][Cl]) with water, acetonitrile, and glucose. For the same systems, experimental viscosity data are provided. The simulation and experimental results were in reasonable agreement. Simulations consistently overestimate the viscosities for th...
Highly selective and sensitive phosphate sensors have been fabricated by constructing a solid membrane disk consisting of variable mixtures of aluminium powder (Al), aluminium phosphate (AlPO4) and powdered copper (Cu). Both binary and ternary electrode systems are produced. The ternary membranes exhibit greater selectivity over a wide range of concentrations. The ternary electrode with the com...
Liquid-Liquid Equilibrium (LLE) data are measured for the ternary mixtures of water + 1-butanol + butyl acetate and quaternary mixtures of water + 1-butanol + butyl acetate + glycerol at atmospheric pressure at 313.15 K. In addition, isothermal vapor–liquid–liquid equilibrium (VLLE) data are determined experimentally at 333.15 K. The region of heterogeneity is found to increase as the hydrophil...
For canonical lipid raft mixtures of cholesterol (chol), N-palmitoylsphingomyelin (PSM), and 1-palmitoyl-2-oleoylphosphatidylcholine (POPC), electron paramagnetic resonance (EPR) of spin-labeled phospholipids--which is insensitive to domain size--is used to determine the ternary phase diagram at 23°C. No phase boundaries are found for binary POPC/chol mixtures, nor for ternary mixtures with PSM...
In this study, a derivative method is applied for the determination of dye concentration in fabrics dyed with tricomponent dye mixtures. The reflectance of spectra of the samples were recorded between 400 and 700 nm. Initially, the obtained (K/S) spectra were divided by the spectrum of a standard sample dyed with two of the components in the ternary mixture and the derivative spectra were calcu...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید