نتایج جستجو برای: thermoluminescence dosimeter

تعداد نتایج: 3015  

2008
Bojana Šećerov Goran Bačić

Radiation processing in many areas, particularly in radiation sterilization, demands control of the absorbed dose. Many dosimeters have been proposed for the high-level dose range (region of 10 to 50 kGy). However, in addition to the required reproducibility, reliability or uncertainty (< 5%), it is desirable for radiation processing that the selected dosimetric system is easy to operate. One o...

Journal: :Medical physics 2015
Kelsey Chisholm Devin Miles Leith Rankine Mark Oldham

PURPOSE In optical-CT, the use of a refractively matched polyurethane solid-tank in place of a fluid bath has the potential to greatly increase practical convenience, reduce cost, and possibly improve the efficacy of flood corrections. This work investigates the feasibility of solid-tank optical-CT imaging for 3D dosimetry through computer simulation. METHODS A matlab ray-tracing simulation p...

Journal: :Chest 2005
Donald W Cockcroft Beth E Davis David C Todd Audrey J Smycniuk

BACKGROUND Guidelines for the 2-min tidal-breathing and the five-breath dosimeter methods for methacholine challenge have recently been published by the American Thoracic Society (ATS). Although subjects are exposed to twice as much aerosol at any given concentration during the tidal-breathing method compared to the dosimeter method, they were thought to give equivalent results. OBJECTIVE To ...

Journal: :The European respiratory journal 1991
A J Knox A Wisniewski S Cooper A E Tattersfield

Bronchial reactivity is being measured with increasing frequency in epidemiological studies, but there debate continues about the relative merits of the different methods used to measure reactivity, particularly for subjects with no previous experience of reactivity testing as is the case in epidemiological studies. Repeatability is likely to improve with practice, and laboratory based studies ...

Journal: :journal of biomedical physics and engineering 0
s. m. j. mortazavi professor of medical physics, department of medical physics and medical engineering, school of medicine, shiraz university of medical sciences, shiraz, iran n. omidifar pathology resident, pathology department, school of medicine, shiraz university of medical sciences, shiraz, iran r. faghihi nuclear engineering department, school of mechanical engineering, shiraz university, shiraz, iran s. mehdizadeh nuclear engineering department, school of mechanical engineering, shiraz university, shiraz, iran s. masoumi the center for radiological research, shiraz university of medical sciences, shiraz, iran s. m. hashemi the center for radiological research, shiraz university of medical sciences, shiraz, iran

background: the number of interventional cardiology procedures performed has increased rapidly over the past years. while these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. the dose received by the cardiologist during interventional cardiology procedures is determi...

Journal: :Chest 2005
Nathan D Allen Beth E Davis Thomas S Hurst Donald W Cockcroft

BACKGROUND Two bronchoprovocation methods are widely used. Compared to the tidal breathing method, the dosimeter method delivers approximately half the dose and involves five deep inhalations. Both the lower dose and the bronchoprotective deep inhalations contribute to the lesser airway response of the dosimeter. OBJECTIVE To determine the relative role of dose and deep inspiration in the dif...

2016
M. Böhm R. Grasser A. Hofstaetter A. Scharmann M. Bohm

— In tungstate and molybdate crystals having scheelite structure various (intrinsic and extrinsic) hole and electron centres are created by X-irradiation at liquid nitrogen temperature. Several of these centres have been thoroughly investigated by electron paramagnetic resonance (EPR) measurements. Their thermal decay and optical bleaching, resp., can be related to glow peaks of thermoluminesce...

2004
K. Koike H. Chihara C. Koike M. Nakagawa M. Okada M. Matsumura J. Takada

the date of receipt and acceptance should be inserted later Abstract. Possible forsterite nanoparticle model of the Extended Red Emission(ERE) is proposed on the basis of photo-luminescence of forsterite after gamma-ray and neutron irradiation. Forsterite exhibits interesting thermoluminescence spectrum similar to ERE of Red Rectangle after irradiation in low temperature. It is shown that the f...

Journal: :Physics in medicine and biology 2015
Y De Deene P S Skyt R Hil J T Booth

Three dimensional radiation dosimetry has received growing interest with the implementation of highly conformal radiotherapy treatments. The radiotherapy community faces new challenges with the commissioning of image guided and image gated radiotherapy treatments (IGRT) and deformable image registration software.A new three dimensional anthropomorphically shaped flexible dosimeter, further call...

2017
H. Amer

In radiation accidents, especially those occuring in residential regions, where the general public may receive a significant dose, it will be very advantageous to define a material that could be easily found in accident location to be used as a radiation dosimeter. One of such materials is the household NaCl that always exist everywhere and could be easily collected. For that reason, the Thermo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید