نتایج جستجو برای: titanium alloy

تعداد نتایج: 83904  

Journal: :Journal of Medical Case Reports 2007
Theodoros B Grivas Olga D Savvidou Spyridon A Psarakis Pierre-Francois Bernard George Triantafyllopoulos Ioannis Kovanis Panagiotis Alexandropoulos

INTRODUCTION Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature. CASE PRESENTATION This case report describes a fracture of the neck of a cement...

Journal: :The Journal of bone and joint surgery. British volume 1992
G L Maistrelli N Mahomed D Garbuz V Fornasier I J Harrington A Binnington

In 33 dogs we implanted femoral stems made either of carbon composite, some coated with hydroxyapatite, or of titanium alloy with a porous coating. Osseointegration was greater in the hydroxyapatite-coated than in the un-coated stems (p less than 0.001). Push-out tests, at an average of 7.2 months after implantation, showed a six-fold increase in interface shear strength and a twelve-fold incre...

Journal: :The Ulster Medical Journal 2003
K. J. Ho E. J. McAteer B. T. Little A. O'Brien

We report on the first case in Ireland of ureteric stenting with shape-memory alloy nickel-titanium (Memokath 051) stent in relieving malignant ureteric obstruction. Successful drainage was achieved and the patient required no further intervention indicating a clear place for these stents in the long-term management of malignant ureteric strictures. The use of ureteric double-J stenting in the ...

2003
F. Lanza G. Bertolini

Previous experiments have shown that tritium is produced in deuterated titanium. To better define the phenomenon a series of tests have been performed using various metals and alloys and different deuterating conditions. Sheets and shavings of titanium, zirconium, hafnium, tantalum, Zircaloy 2 and Ti-Zr 50% alloy have been tested. A statistical analysis of the tritium production shows that sign...

Journal: :The International journal of oral & maxillofacial implants 2001
Y J Lim Y Oshida C J Andres M T Barco

The attachment of cells to titanium surfaces is an important phenomenon in the area of clinical implant dentistry. A major consideration in designing implants has been to produce surfaces that promote desirable responses in the cells and tissues. To achieve these requirements, the titanium implant surface can be modified in various ways. This research was designed to elucidate the relationship ...

2013
YUQUAN HAO SHUJUN LI XUESONG HAN YULIN HAO HONGJUN AI

The aim of the present study was to investigate the effects of the surface characteristics of nanoporous titanium oxide films, formed by anodization on Ti-24Nb-4Zr-8Sn (Ti2448) alloy, on the early adhesion of osteoblast-like MG-63 cells. Nanoporous titanium oxide films with two different pore sizes (30 and 90 nm) were formed by anodization in NH4F solution on Ti2448 alloy. The surface roughness...

2007
Bogdan Walkowiak Ksenia Bykowska

Significant progress made in materials science, mainly in the technology of surface, allows for intentional modifications of metallic surfaces. Thin layers of modified surfaces separate metallic substrates from environment and prevent them from corrosion. However, a real opportunity to control the interaction of surface with surrounding tissues and body fluids, with respect to the anticipated a...

Sabokrouh , M. ,

In this article the effects of carburizing heat treatment on girth weld with containing titanium oxide and titanium carbide nanoparticles (X-65 grade of gas pipeline) is evaluated. The charpy results show that in the carburized sample containing titanium oxide and titanium carbide nanoparticles compared to the no heat treatment sample (containing titanium carbide and titanium carbide nanopartic...

Journal: :The International journal of oral & maxillofacial implants 2013
Gianluca Paniz Edoardo Stellini Roberto Meneghello Andrea Cerardi Edoardo Alvise Gobbato Eriberto Bressan

PURPOSE The purpose of this study was to investigate the marginal precision of computer numeric control-milled frameworks fabricated of grade 4 commercially pure titanium or cobalt-chrome alloy through digital technology and to compare them with conventional cast frameworks. MATERIAL AND METHODS A titanium cast of a mandibular arch with six implant analogs was used as a master. The master cas...

2013
Esther T. Akinlabi Mukul Shukla Stephen A. Akinlabi

Laser beam forming is a novel technique developed for the joining of metallic components. In this study, an overview of the laser beam forming process, areas of application, the basic mechanisms of the laser beam forming process, some recent research studies and the need to focus more research effort on improving the laser-material interaction of laser beam forming of titanium and its alloys ar...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید