Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...
Dose distributions for photon beam were measured using a Photo-Stimulated Luminescence Dosimeter (PSLD) sheet, which has 18 x 24 cm dimension and 0.2 mm thickness. Its density and effective atomic number are 1.0 g/cm and 7.6, respectively. The read out was performed by blue LED lights for 20 seconds, which was much shorter than the readout time for TLD. The percent depth dose and dose profile w...
96 Since its development, the Early Warning dosimeter for Organic materials (EWO dosimeter) has been used as both a research and general measurement tool for the evaluation of indoor air quality for preservation of cultural heritage artefacts. The EWO dosimeter measures the integrated degradation impact of the environment, comparable to that observed on organic materials due to the synergistic ...
Problem statement: Diagnosis x-ray radiation safety is key in medical examination. The quantity of patient radiation doses is beneficial for radiation protection of the patient. It was proposed that the equation for estimating the output (milliReongent, mR) from x-ray machines. Approach: A was 0.5, 0.8 and 1.0 for single phase, three phases and high frequency x-ray machines, respectively. To co...
Post-irradiation stability of high-dose dosimeters has traditionally been an important measurement influence quantity. Though the exceptional stability of the alanine dosimeter response with time has rendered this factor a non-issue for routine work, the archival quality of the alanine dosimeter has not been characterized. Here the alanine pellet dosimeter response is measured up to seven years...
An a-Si Active Matrix Flat Panel Imager (AMFPI) prototype developed in-house has been modified to function as an in-phantom dosimetry system providing high resolution two-dimensional (2-D) data. This Active Matrix Flat Panel Dosimeter (AMFPD) system can be used as a replacement device for standard in-phantom dosimeters, such as scanning ion chambers in water, or film in solid water. The initial...
While scintillation dosimetry has been around for decades, the need for a dosimeter tailored to the reality of modern radiation therapy-in particular a real-time, water-equivalent, energy-independent dosimeter with high spatial resolution-has generated renewed interest in scintillators over the last 10 years. With the advent of at least one commercial plastic scintillation dosimeter and the eve...
Abstract Twin-screw expanders are widely used for small to medium-sized organic Rankine cycle (ORC) power generation. In order improve the performance of twin-screw in ORC, this study aims inlet efficiency and reduce pressure loss by changing geometry shell. The CFD transient simulation is pressure, gas flow conditions other parameters working chamber that not easily obtained through experiment...
Magnetic resonance imaging (MRI) is being rapidly integrated for cancer treatments-such systems are referred to as MRI-guided radiation therapy (MRIgRT). As the magnet of an MRI scanner is always on, the presence of a strong static magnetic field from the MRI scanner during radiotherapy delivery presents new challenges. One of the challenges is that a personal radiation dosimeter used to estima...