Tatsuro Sasaji Hideki Imaizumi Taishi Murakami

Low transverse sacral fractures are rare, with only two published reports regarding their surgery. The complication associated with surgery for sacral fractures is the prominence of implants. In addition, screw fixation below S3 is impractical. We performed posterior sacral fixation using S2 alar iliac (S2AI) screws and sacral sublaminar wires for low transverse sacral fractures. Case 1 was 65-...

Journal: :The Journal of bone and joint surgery. British volume 1998
H Minakawa M H Stone B M Wroblewski J G Lancaster E Ingham J Fisher

We examined stainless-steel, cobalt-chrome, titanium and alumina and zirconia ceramic femoral heads retrieved at revision surgery. All the heads had articulated against ultra-high-molecular-weight-polyethylene (UHMWPE) acetabular cups. We studied the simulation of third-body damage and the wear of UHMWPE against the various materials used for the heads. The surfaces of the retrieved heads were ...

Journal: :Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2013
Abdellatif Abdelgaied Claire L Brockett Feng Liu Louise M Jennings John Fisher Zhongmin Jin

Polyethylene wear is a great concern in total joint replacement. It is now considered a major limiting factor to the long life of such prostheses. Cross-linking has been introduced to reduce the wear of ultra-high-molecular-weight polyethylene (UHMWPE). Computational models have been used extensively for wear prediction and optimization of artificial knee designs. However, in order to be indepe...

Journal: :Journal of biomedical materials research. Part B, Applied biomaterials 2009
Ryan M Baxter Marla J Steinbeck Joanne L Tipper Javad Parvizi Michele Marcolongo Steve M Kurtz

There is considerable interest in characterization of wear debris from polyethylene (UHMWPE) bearing components used in total joint replacement. To isolate UHMWPE wear debris, tissue samples must be excised from regions adjacent to revised UHMWPE implant components, followed by exposure to one of many available tissue digestion methods. Numerous studies demonstrate successful digestion, but the...

Journal: :Biomaterials 2003
S J Charlebois A U Daniels G Lewis

In this work, isothermal microcalorimetry (IMC) was utilized to measure the exothermic heat flow from specimens of ultra-high-molecular-weight polyethylene (UHMWPE), that had been sterilized by various standard methods, under simulated shelf storage (air at 25 degrees C, 30% r.h.) and simulated implantation (phosphate buffered saline, PBS, at 37 degrees C) conditions. Gamma-radiation sterilized...

Journal: :Journal of biomedical materials research. Part B, Applied biomaterials 2010
Angela L Bruck K S Kanaga Karuppiah Sriram Sundararajan Jun Wang Zhiqun Lin

In this study, the friction and wear behavior of ultrahigh molecular weight polyethylene (UHMWPE) were evaluated as a function of polymer crystallinity in the presence of the phospholipid dipalmitoyl phosphatidylcholine (DPPC) dissolved in ethanol. Samples of UHMWPE were separately heat treated to get high and low crystallinity samples. Degree of crystallinity was evaluated using differential s...

2011
C. J. F. Brown

INTRODUCTION Concerns regarding UHMWPE wear particle induced osteolysis [1] have led to investigations of alternative bearing materials. Carbon-fibre reinforced poly-ether-ether-ketone (CFR-PEEK) has been shown in animal studies to have a similar biological activity to UHMWPE [2], whilst hip and knee configurations incorporating this polymer display reduced wear rates when compared with convent...

2013
Aaron P. Essner

THE MORPHOLOGY OF UHMWPE WEAR DEBRIS GENERATED BY A HIP JOINT SIMULATOR

The use of UHMWPE has attracted the attention of many researchers and industries. The aim of the present work is to fabricate UHMWPE/MoS2-Oxide nano-composites using in-situ polymerization. For this purpose, modified molybdenum disulfide was used. In order to perform the polymerization, a Ziegler-Natta catalytic system, with MoS2-Oxide and magnesium Ethoxide as support, was used. In order to fa...

نمودار تعداد نتایج جستجو در هر سال