Polymer Bonded Explosives (PBX) are well-known explosives for the weapons, especially for the parts of some important weapon. Generally, they first are modelled in cylinder. One of the most important issues in PBX cylinder properties is the detection of its flaw. Each PBX cylinder may have flaws that influence the security, machine-performance and other important physical or chemical performanc...
This paper describes the design of a pulse generator based on the Programmable System-on-Chip (PSoC) module. In this module, using programmable logic is possible to implement different pulses which are required for ultrasonic applications, either in a single channel or multiple channels. This module can operate with programmable frequencies from 3-74 MHz; its programming may be versatile coveri...
Qualifying an anechoic chamber for frequencies that extend into the ultrasonic range is necessary for research work involving airborne ultrasonic sound. The ANSI S12.55/ISO 3745 standard which covers anechoic chamber qualification does not extend into the ultrasonic frequency range, nor have issues pertinent to this frequency range been fully discussed in the literature. An increasing number of...
The proposed technology aims to enable 3D localization of scatterers using single element ultrasonic transducers, which are traditionally limited 1D measurements. This is achieved by designing a bespoke acoustic lens with spiral-shaped pattern similar the human outer ear, shape that has evolved for sound source localization. breaks surface symmetry transducer, allowing waves arriving from diffe...
The reproducibility of ultrasonic measurements complicates the interpretation of measurement results. The signal from ultrasonic transducers varies for to several reasons, like manufacturing tolerances in a batch, cable length, amplifier properties etc. A known problem that is caused by this effect is the quantitative interpretation of C-scan images from laminates, particularly the porosity pre...
Achieving accurate measurements of inflammation levels in tissues or thickness changes in biological membranes (e.g., amniotic sac, parietal pleura) and thin biological walls (e.g., blood vessels) from outside the human body, is a promising research line in the medical area. It would provide a technical basis to study the options for early diagnosis of some serious diseases such as hypertension...
AbstmclIn this paper, a 400-pm x 40C-prn, 2-D eapacitive micromachined ultrasonic transducer array element is experimentally characterized, and the results are found to be in agreement with theoretical predictions. As a receiver the transducer has a 1.8 x lo-' n m / m displacement sensitivity, and, as a transmitter, it produces 16.4 kPa/V of output pressure at the transducer surface at 3 MHz. T...