نتایج جستجو برای: voxelized phantom
تعداد نتایج: 17420 فیلتر نتایج به سال:
In this paper we introduce algorithms to voxelize polygonal meshes in common sampling lattices. In the case of Cartesian lattices, we complete the separability and minimality proof for the voxelization method presented by Huang et al [5]. We extend the ideas to general 2D lattices, including hexagonal lattices, and 3D body-centred cubic lattices. The notion of connectedness in the two lattice s...
We present a novel extension to shape grammars, in which the generated shapes are voxelized. This allows easy Boolean geometry operations on the shapes, and detailing of generated models at a sub-shape level, both of which are extremely difficult to do in conventional shape grammar implementations. We outline a four step algorithm for using these extensions, discuss a number of optional enhance...
Monte Carlo codes are utilized for accurate dose calculations in proton radiation therapy research. While they are superior in accuracy to commonly used analytical dose calculations, they require significantly longer computation times. The aim of this work is to characterize a Monte Carlo track-repeating algorithm to increase computation speed without compromising dosimetric accuracy. The track...
We explore real time volume rendering of multichannel data for volumes with color and multi-modal information. We demonstrate volume rendering of the Visible Human Male color dataset and photo-realistic rendering of voxelized terrains, and achieve high quality visualizations. We render multi-modal volumes utilizing hardware programmability for accumulation level mixing, and use CT and MRI infor...
We present a method to incrementally voxelize triangles into a volumetric dataset with pre-filtering, generating an accurate multivalued voxelization. Multivalued voxelization allows direct volume rendering of voxelized geometry as well as volumes with intermixed geometry, accurate multiresolution representations, and efficient antialiasing. Prior voxelization methods either computed only a bin...
Within the framework of radiation protection or internal radiotherapy, one of the major stakes is to determine in a most realistic possible way the dose received by every patient. In this purpose, a tool called OEDIPE, French acronym for “tool for personalized internal dose assessment”, was developed at IRSN associating numerical voxelized phantoms, created with anatomical images, and Monte Car...
This paper describes a new architecture for generating smoothly shaded two dimensional images of volume data. This architecture ts into an image synthesis pipeline and uses only simple arithmetic operations and a look-up table to generate two dimensional images in real time. The shading algorithm is an extension of the grey-level gradient algorithm for shading volume data. The shading technique...
introduction: poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. scattered photons are the main cause of degrading the contrast and resolution in spect imaging that result in error in quantification. thallium decay is very complicated and photons ar...
Optical pump-probe setups are commonly used for excitation and investigation of the spin dynamics in various types magnetic materials. Usually spatially homogeneous is considered, but here authors describe optical $n\phantom{\rule{0}{0ex}}o\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}u\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}f\phantom{\rule{0}{0ex}}o\phantom{\rul...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید