نتایج جستجو برای: 3D Treatment Planning

تعداد نتایج: 1749727  

Journal: :iranian journal of medical physics 0
zahra falahatpour m.sc. graduate of medical radiation, nuclear engineering dept., faculty of nuclear engineering, shahid beheshti university, tehran, iran seyed mahmood reza aghamiri associate professor, nuclear engineering dept., faculty of nuclear engineering, shahid beheshti university, tehran, iran robab anbiaee assistant professor, radiotherapy and oncology dept., emam hossein hospital, shahid beheshti university, tehran, iran

introduction: breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. a tangential parallel-opposed pair is usually used for this purpose. this technique is performed using 2d or 3d treatment planning systems. the aim of this study was to compare 2d treatment planning with 3d treatment planning in tangential irradiation in breast conse...

Robab Anbiaee Seyed Mahmood Reza Aghamiri, Zahra Falahatpour

Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...

Journal: :iranian journal of medical physics 0
robab anbiaee assistant professor, radiotherapy and oncology dept., imam hossein hospital, shahid beheshti university, tehran, iran seyed mahmoud reza aghamiri associate professor, nuclear engineering-medical radiation dept., faculty of nuclear engineering, shahid beheshti university, tehran, iran zahra falahatpour m.sc in nuclear engineering-medical radiation, faculty of nuclear engineering, shahid beheshti university, tehran, iran

introduction: radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. a tangential parallel-opposed pair is almost always the technique of choice for this purpose. this technique is often performed based on 3d treatment planning. the aim of this study was to compare 3d treatment planning for two different energie...

Journal: :basic and clinical cancer research 0
kaveh shirani tak abi department of engendering, science and research branch, islamic azad university, tehran, iran hassan ali nedaie department of medical physics, tehran university of medical science, tehran, iran. hossein hassani department of engendering, science and research branch, islamic azad university, tehran, iran mansour naderi m.sc of medical physics, radiotherapeutic oncology department of cancer institute mohammad babaie radiotherapy oncology department, cancer institute, tehran university of medical science, theran, iran mahmood samei radiotherapeutic oncology, radiation oncology center of karaj, iran

the aim of radiation therapy treatment planning is to achieve an optimal balance between delivering a high dose to target volume and a low dose to healthy tissues. in order to refrain any complications resulting from the dose to the surrounding normal organs, the role of treatment plan has been critically evaluated in term of how large the volume or mass of normal tissues exposed in the radiati...

Journal: :Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons 2009
Gwen R J Swennen Wouter Mollemans Filip Schutyser

PURPOSE The aim of this report was to present an integrated 3-dimensional (3D) virtual approach toward cone-beam computed tomography-based treatment planning of orthognathic surgery in the clinical routine. MATERIALS AND METHODS We have described the different stages of the workflow process for routine 3D virtual treatment planning of orthognathic surgery: 1) image acquisition for 3D virtual ...

Robab Anbiaee Seyed Mahmoud Reza Aghamiri, Zahra Falahatpour

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

Background: Radiotherapy with large mantle field is an effective technique in increasing the risk of secondary cancers among HL (Hodgkin Lymphoma) patients; therefore, it is essential to choose an effective treatment field including the least medical conditions in radiotherapy.Objective: The present study aimed to plan separate fields for neck and mediastinum using various energies, to compare ...

اصفهانی, مهبد , حداد, پیمان , سمیعی, فرهاد , عصمتی, ابراهیم , عقیلی, مهدی , مشتاقی, مریم , ندائی, حسنعلی ,

Background: The current standard of adjuvant management for gastric cancer after curative resection based on the results of intergroup 0116 is concurrent chemoradiation. Current guidelines for designing these challenging fields still include two-dimensional simulation with simple AP-PA parallel opposed design. However, the implementation of radiotherapy (RT) remains a concern. Our objective was...

ژورنال: کومش 2020
Abedi, Iraj, Akbari-Zadeh, Hadi, Amouheidari, Alireza, Saadatmand, Pegah, Shanei, Ahmad,

Introduction: The purpose of this study was to evaluate the dosimetric and radiobiological parameters of salivary glands in treatment of patients with oral tongue cancer by 3D conventional radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Materials and Methods: This study was performed on treatment planning of patients with oral tongue cancer in T2-3/N0 cancer s...

Journal: :iranian journal of radiation research 0
t. siji cyriac department of physics, noorul islam centre for higher education, kumaracoil, thuckalay, kanyakumari district, 629 180, tamilnadu, india m.m. musthafa department of physics, university of calicut, thenhipalam, malappuram, 673 635, kerala, india r. ganapathi raman department of physics, noorul islam centre for higher education, kumaracoil, thuckalay, kanyakumari district, 629 180, tamilnadu, india k. abdul haneefa infn and department of physics, university of torino, via p. giuria, 10125, torino, italy saju bhasi department of radiation physics, regional cancer center, trivandrum, 695 011 , kerala, india

background: the present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (tps), oncentra, for three-dimensional conformal radiotherapy (3d-crt) and intensity modulated radiation therapy (imrt) treatment techniques from elekta synergy medical linear accelerator. materials and methods: accuracy of individual out-of-field dose components was...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید