نتایج جستجو برای: CTDIvol

تعداد نتایج: 129  

2016
Sameer Tipnis Rajesh Thampy Zoran Rumboldt Maria Spampinato Gisele Matheus Walter Huda

The purpose of this study was to quantify how changing the amount of radiation used to perform routine head CT examinations (CTDIvol) affects visibility of key anatomical structures. Eight routine noncontrast head CT exams were selected from six CT scanners, each of which had a different CTDIvol setting (60 to 75 mGy). All exams were normal and two slices were selected for evaluation, one at th...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2016
Ngoneh Jallow Paul Christian John Sunderland Michael Graham John M Hoffman Jonathon A Nye

UNLABELLED The role of CT in PET/CT imaging includes acquisition techniques for diagnostic, anatomic localization, and attenuation correction purposes. Diagnostic reference levels of the volumetric CT dose index (CTDIvol) are available for dedicated CT procedures on selected body regions, but similar reference levels for whole-body CT used in PET/CT examinations are limited. This work reports C...

Journal: :Journal of the American College of Radiology : JACR 2014
J Anthony Seibert John M Boone Sandra L Wootton-Gorges Ramit Lamba

PURPOSE The volume CT dose index (CTDIvol) and the dose-length product, commonly reported for examinations performed on clinical CT scanners, should not be used as surrogates for patient dose. This is because significant under or overestimates of these actual values can occur when there is a mismatch between the actual body size of the patient and the 16 cm or 32 cm diameter CTDIvol phantoms. T...

2016
Matthew T. Dixon Robert J. Loader Gregory C. Stevens Nick P. Rowles

Organ Dose Modulation or ODM (GE Healthcare, Milwaukee, WI) was evaluated to characterize changes in CTDIvol, image noise, effective dose, and organ dose saving to patients. Three separate investigations were completed: a tube current modulation phantom was scanned with and without ODM, a CTDIvol phantom was scanned with ODM, and Monte Carlo simulations were performed. ODM was found to reduce t...

2018
Sandra Sarmento Bruno Mendes Margarida Gouvêa

OBJECTIVES To compare the effectiveness of two different patient size metrics based on water equivalent diameter (Dw ), the mid-scan water equivalent diameter Dw_c , and the mean (average) water equivalent diameter in the imaged region, Dw_ave , for automatic detection of accidental changes in computed tomography (CT) acquisition protocols. METHODS Patient biometric data (height and weight) w...

2016
Leland Page Wei Wei Vikas Kundra X. John Rong

To evaluate the feasibility of radiation dose reduction using model-based iterative reconstruction (MBIR) for evaluating the ureters and vasculature in a phantom, a tissue-equivalent CT dose phantom was scanned using a 64-channel CT scan-ner. Tubes of varying diameters filled with different dilutions of a contrast agent, simulating ureters or vessels, were inserted into the center of the phanto...

2016
Gareth R. Iball Alexis C. Moore Elizabeth J. Crawford

The study purpose was to develop and validate a quality assurance test for CT automatic exposure control (AEC) systems based on a set of nested polymethylmethacrylate CTDI phantoms. The test phantom was created by offsetting the 16 cm head phantom within the 32 cm body annulus, thus creating a three part phantom. This was scanned at all acceptance, routine, and some nonroutine quality assurance...

2016
J. Boos A. Meineke C. Rubbert P. Heusch R. S. Lanzman J. Aissa G. Antoch P. Kröpil

Ziel: Ziel dieser Studie war die Implementierung eines Cloud-basierten CT-Dosismonitorings basierend auf demDICOM-Structured Report (DICOM-SR) zur automatischen Überwachung der Dosisexposition im Hinblick auf die nationalen diagnostischen Referenzwerte (DRW). Material und Methoden: Zur automatischen Erfassung und Überwachung der CT-Dosisdaten wurde eine neuartige, in Kooperation mitentwickelte ...

Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...

Journal: :Atom Indonesia 2022

The dose received by a patient on CT examination is expressed in size-specific estimates (SSDE) which function of the diameter, x-ray attenuation, and scanner output (volume computed tomography index, CTDIvol). Patient diameter attenuation are represented as water equivalent (Dw). We conducted research to analyze relationships between body weight Dw, CTDIvol, contrast-enhanced thorax examinatio...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید