نتایج جستجو برای: Distal edge

تعداد نتایج: 181973  

Journal: :iranian journal of veterinary research 2011
f. ramezani nowrozani

one of the locations of renal artery atherosclerosis is at the orifice of the renal artery, therefore thestructure of this orifice was assessed in 6 normal, adult male dogs by light microscopy (lm) andtransmission electron microscopy (tem). for the lm study, processed tissues were embedded in paraffinand sectioned serially into 6-μm thickness. sections were stained with orcein. for the tem stud...

One of the locations of renal artery atherosclerosis is at the orifice of the renal artery, therefore thestructure of this orifice was assessed in 6 normal, adult male dogs by light microscopy (LM) andtransmission electron microscopy (TEM). For the LM study, processed tissues were embedded in paraffinand sectioned serially into 6-μm thickness. Sections were stained with orcein. For the TEM stud...

Journal: :Journal of Neurology & Neurophysiology 2013

2010
Kithsiri J. Senanayake

Transligamentous variant of the recurrent motor branch is having a higher risk of getting damage during both endoscopic and open carpal tunnel releases. The incidence of the transligamentous variant is about 7% to 80% world wide. This wide variation of the incidence could be due to the failure of identification of the distal edge of the flexor retinaculum from the obliquely oriented fascia that...

Journal: :The American journal of cardiology 2006
Tatsuhiko Asano Yoshio Kobayashi Gary S Mintz Naoki Ishio Shigenori Fujimaki Yasuhide Ogawa Takashi Nakayama Nakabumi Kuroda Issei Komuro

Serial (baseline and 9-month follow-up) intravascular ultrasound analysis was performed at 5-mm reference segments immediately proximal and distal to the sirolimus-eluting stent (SES) in 33 lesions. Proximal and distal reference segments were divided into 1-mm subsegments. Between postintervention and follow-up intravascular ultrasound studies, there were significant decreases in the lumen and ...

Journal: :Circulation. Cardiovascular interventions 2016
Nobuaki Kobayashi Gary S Mintz Bernhard Witzenbichler D Christopher Metzger Michael J Rinaldi Peter L Duffy Giora Weisz Thomas D Stuckey Bruce R Brodie Rupa Parvataneni Ajay J Kirtane Gregg W Stone Akiko Maehara

BACKGROUND Intravascular ultrasound detects stent edge dissections after percutaneous coronary intervention that are not seen angiographically. This study investigated the association between stent edge dissections and clinical outcomes. METHODS AND RESULTS ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a large-scale, prospective, multicenter study of patient...

Journal: :Eplasty 2008
Ron Hazani Nitin J. Engineer Arian Mowlavi Michael Neumeister W.P. Andrew Lee Bradon J. Wilhelmi

BACKGROUND The posterior interosseous nerve (PIN) can be difficult to locate within the radial tunnel. The deep branch of the radial nerve (DBRN) enters the supinator muscle after passing under the arcade of Fröhse. It courses through the superficial portion of the supinator muscle to exit distally as the PIN. Anatomic landmarks could facilitate diagnosis and treatment of radial tunnel syndrome...

Journal: :Circulation 2002
Edouard Cheneau Ron Waksman Hamid Yazdi Rosanna Chan Jana Fourdnadjiev Chalak Berzingi Vivek Shah Andrew E Ajani Laurent Leborgne Fermin O Tio

BACKGROUND Edge stenosis remains a serious limitation of catheter-based vascular brachytherapy (VBT). This study aims to identify the mechanisms and evaluate strategies to minimize edge restenosis in patients treated with VBT. METHODS AND RESULTS Thirty-four porcine stented coronary arteries were irradiated (doses of 15 or 22 Gy) with (192)Ir trains of either 6 seeds (23 mm) with 0 mm coverag...

Journal: :Revista brasileira de ortopedia 2011
Ricardo de Paula Leite Cury Nilson Roberto Severino Osmar Pedro Arbix Camargo Tatsuo Aihara Leopoldo Viana Batista Neto Dedley Nelson Goarayeb

OBJECTIVE To identify objective parameters to guide correct location of the posterior cruciate ligament (PCL) in the femur. METHODS The PCLs of 20 human cadavers were resected. The following portions were measured: distance from the most distal portion of the PCL, close to the roof, to the most anterior edge of the cartilage (AB); distance from the most proximal portion of the PCL, close to t...

Journal: :Journal of experimental psychology. Learning, memory, and cognition 2014
Weimin Mou Jean-François Nankoo Ruojing Zhou Marcia L Spetch

Five experiments investigated how human adults use landmark arrays in the immediate environment to reorient relative to the local environment and relative to remote cities. Participants learned targets' directions with the presence of a proximal 4 poles forming a rectangular shape and an array of more distal poles forming a rectangular shape. Then participants were disoriented and pointed to ta...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید