نتایج جستجو برای: Dose Calculation Algorithm

تعداد نتایج: 1144675  

Journal: :iranian journal of radiation research 0
y.l. kim department of radiology, choonhae college of health science, ulsan 689-784, south korea t.s. suh department of radiology, choonhae college of health science, ulsan 689-784, south korea b.y. choe department of radiology, choonhae college of health science, ulsan 689-784, south korea b.o. choi department of radiation oncology, seoul st. mary’s hospital, the catholic university, seoul 137-701, south korea j.b. chung department of radiadion oncology, seoul national university bundang hospital, seongnam 463-707, south korea j.w. lee department of radiation oncology, konkuk university medical center, seoul 143-729, south korea

background: dose calculation algorithms play a very important role in predicting the explicit dose distribution. we evaluated the percent depth dose (pdd), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. materials and methods: the homogeneous and inhomogeneous virtual slab phantoms used in th...

B.M. Park, B.O. Choi, B.Y. Choe, J.B. Chung, J.W. Lee, J.Y. Jung, T.S. Suh, Y.J. Shin, Y.K. Bae, Y.L. Kim,

Background: Dose calculation algorithms play a very important role in predicting the explicit dose distribution. We evaluated the percent depth dose (PDD), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. Materials and Methods: The homogeneous and inhomogeneous virtual slab phantoms used in th...

Azizollah Rahimi Mansour Zabihzadeh Mozafar Naserpour, Sasan Razmjoo Sholeh Arvandi Syyed Mohammad Hoseini

Introduction: Each treatment planning algorithm has some errors in dose calculation. Particularly these errors are more pronounced in the heterogeneous regions. It is recommended for each set of radiation data and algorithm subtle deliberation done regarding dose calculation accuracy. Knowing the amount of error in dose calculation will result in a fairly accurate estimate of t...

Journal: :iranian red crescent medical journal 0
sedigheh sina radiation research center, shiraz university, shiraz, ir iran reza faghihi radiation research center, shiraz university, shiraz, ir iran; department of nuclear engineering, shiraz university, shiraz, ir iran; radiation research center, shiraz university, shiraz, ir iran. tel: +98-7116473474, fax: +98-7116473474 ali soleimani meigooni department of nuclear engineering, shiraz university, shiraz, ir iran; comprehensive cancer center of nevada, las vegas, nevada, usa zahra siavashpour department of radiation medicine, shahid beheshti university, tehran, ir iran mohammad amin mosleh-shirazi center for research in medical physics and biomedical engineering, shiraz university of medical sciences, shiraz, ir iran; department of radiotherapy and oncology, shiraz university of medical sciences, shiraz, ir iran

conclusions according to the results, the old dosimetry formalisms, overestimate the dose especially towards the applicator’s tip. while the tg-43u1 based software perform the calculations more accurately. results for a typical arrangement of 10 active pellets in the applicator, the percentage difference between doses obtained by the new algorithm at 1cm distance from the tip of the applicator ...

Hassan Ali Nedaie, Mahbod Esfahani Nasibeh Kavousi Somayeh Gholami,

Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...

Journal: :iranian journal of medical physics 0
asghar mesbahi department ofmedical physics, medical school, tabriz university of medical sciences,,tabriz, iran. 2- department ofradiation oncology, imam hospital, tabriz, iran. ismail zergoug 3-department of radiotherapy, emir abdelkaderanti-cancer center, oran, algeria

introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...

Journal: :iranian journal of medical physics 0
hamid-reza sadoughi medical physics research center, medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran shahrokh nasseri medical physics research center, medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran mahdi momennezhad medical physics research center, medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran imam reza hospital, mashhad university of medical sciences, mashhad, iran hadi sadoghi-yazdi department of computer engineering, ferdowsi university of mashhad, mashhad, mohammad-hossein bahreyni-toosi medical physics research center, medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran

introduction relative dose computation is a necessary step in radiation treatment planning. therefore, finding an approach that is both fast and accurate seems to be necessary. the purpose of this work was to investigate the feasibility of natural cubic spline to reconstruct dose maps for linear accelerator radiation treatment fields in comparison with those of the simulation. materials and met...

نمودار تعداد نتایج جستجو در هر سال