نتایج جستجو برای: Dosimetric Phantoms
تعداد نتایج: 17366 فیلتر نتایج به سال:
background: electronic portal imaging devices (epids) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. a successful utilization of epids for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. in this study, two in-house phantoms were developed and analyzed for implementation in a qua...
introduction accurate estimation of the absorbed dose in radiosensitive organs, located away from the target volume during radiotherapy, is one of the main reasons for the development of reference phantoms. the international commission on radiological protection (icrp) reference phantoms can provide a more realistic view of the human anatomy in comparison with the previously used mathematical p...
Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...
A standard protocol of dosimetric measurements is used by the organizations responsible for verifying that the doses delivered in radiation-therapy institutions are within authorized limits. This study evaluated a self-designed simple auditing phantom for use in verifying the dose of radiation therapy; the phantom design, dose audit system, and clinical tests are described. Thermoluminescent do...
Dosimetric modeling of radiation transport in skeletal bone tissues using computational phantoms provides the doses internal exposure to active marrow. Computational ICRP are created for reference people with anatomical and physiological characteristics typical an average individual. The calculated such will correspond certain population-average values. Individual variability introduce a stocha...
background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...
introduction based on task group no. 43 (tg-43u1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. the experimental determination of tg-43 parameters is usually performed in water-equivalent solid phantoms. the purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. materials and methods t...
The purpose of this study is to compare performance of several dosimetric meth-ods in heterogeneous phantoms irradiated by 6 and 18 MV beams. Monte Carlo (MC) calculations were used, along with two versions of Acuros XB, anisotropic analytical algorithm (AAA), EBT2 film, and MOSkin dosimeters. Percent depth doses (PDD) were calculated and measured in three heterogeneous phantoms. The first two ...
The purpose of this study was the dosimetric evaluation of thermoluminescent detectors of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by IPEN compared to the TL response of lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti) dosimeters and microdosimeters produced by Harshaw Chemical Company to clinical photon beams dosimetry (6 and 15 MV) using liquid water and PMMA p...
Background: Electronic portal imaging devices (EPIDs) play an important role in radia on therapy portal imaging, geometric and dosimetric verifica ons. A successful u liza on of EPIDs for imaging and dosimetric purposes requires a reliable quality control process rou ne to be carried out regularly. In this study, two in‐house phantoms were developed and analyzed for implementa on in a quality a...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید