نتایج جستجو برای: Electron dosimetry

تعداد نتایج: 315962  

Journal: :iranian journal of medical physics 0
zahra anjomani m.sc. in medical physics, nuclear engineering dept., shahid beheshti university, tehran, iran hasan nedaie assistant professor, radiotherapy physics dept., tehran university of medical science, tehran, iran majid shariari associate professor, nuclear engineering dept, shahid beheshti university, tehran, iran

introduction: nowadays new radiochromic films have an essential role in radiotherapy dosimetry. properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. material and methods: in this study, electron-beam dose distributions in homogenous and heterogeneous pha...

2009
M. F. Desrosiers J. M. Puhl

Over the course of the last decade, routine monitoring of the alanine dosimetry system revealed a small but significant observation that, after examination, led to the characterization of a previously unknown absorbed-dose-dependent, dose-rate effect for the alanine system. The newly discovered rate effect is of potential concern for electron-beam dosimetry, since electron-beam dosimetry typica...

Journal: :Brazilian Journal of Radiation Sciences 2023

The Technical Report Series 398 (TRS-398), Electron Dosimetry Working Party (EWDP), and Task Group 51 (TG 51) are the most important protocols for reference dosimetry. In case of electron beam dosimetry, these recommend using parallel-plate ionization chambers beams with R50 values below specific thresholds. However, recent papers suggested cylindrical dosimetry all energies. Here we compared d...

Hasan Nedaie Majid Shariari Zahra Anjomani,

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m r bayatiani arak university of medical sciences

background: megavoltage beams used in radiotherapy are contaminated with secondary electrons. different parts of linac head and air above patient act as a source of this contamination. this contamination can increase damage to skin and subcutaneous tissue during radiotherapy.  monte carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

Journal: :iranian journal of science and technology (sciences) 2008
a. akhavan

in order to improve the performance of a newly developed radiochromic film, gic-79, somedosimetric characteristics of this film have been studied based on relevant standard practice. the presentstudy describes some parameters that may affect the dosimeter response before, during, and after irradiation. the effect of absorbed dose rate on dosimeter response was determined by irradiating dosimete...

Journal: :Stem cells 1997
T Straume L R Anspaugh E H Haskell J N Lucas A A Marchetti I A Likhtarev V V Chumak A A Romanyukha V T Khrouch Gavrilin YuI V F Minenko

In this article we discuss examples of challenging problems in retrospective dosimetry and describe some promising solutions. The ability to make measurements by accelerator mass spectrometry and luminescence techniques promises to provide improved dosimetry for regions of Belarus, Ukraine and Russian Federation contaminated by radionuclides from the Chernobyl accident. In addition, it may soon...

Journal: :iranian journal of radiation research 0
c.a. davis department of radiotherapy, national oncology center, royal hospital, muscat, sultanate of oman r. ravichandran department of radiotherapy, national oncology center, royal hospital, muscat, sultanate of oman j.p. binukumar department of radiotherapy, national oncology center, royal hospital, muscat, sultanate of oman k. el ghamrawy department of radiation oncology, university of cairo, cairo, egypt

background: for radiotherapy of total skin including sub-cutaneous tissue up to a depth of 3 cm on the entire left leg of an adult (angiosarcoma skin), a complex treatment with multiple stationary electron fields was planned at our clinic. the details of dosimetry, clinical dose measurements are presented. materials and methods: the treatment planned with 6 overlapping 9 mev electron fields in ...

Journal: :Medical physics 2008
Fujio Araki

Recent standard dosimetry protocols recommend that plane-parallel ionization chambers be used in the measurements of depth-dose distributions or the calibration of low-energy electron beams with beam quality R50 <4 g/cm2. In electron dosimetry protocols with the plane-parallel chambers, the wall correction factor, Pwall, in water is assumed to be unity and the replacement correction factor, Pre...

2004
Božidar Casar Urban Zdešar Vlado Robar

Introduction. In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency (IAEA), water is recommended as the reference medium for the determination of absorbed dose for high-energy electron beams. Plastic phantoms may be used under certain circumstances for electron beam dosimetry for beam qualities R50 < 4g/cm2 (E0 below 10 MeV). In our study, w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید