in this research work, alpha particle detector is made using semi-insulating gaas. a surface barrier detector with a semi-insulating gaas substrate at room temperature with pressure of 10-4 torr under -particle radiation with 5.48 mev of am241 source, have been under investigation. energy resolution of 2 and 3 mm schottky diameter have been matured and compared with the effect of voltage varia...

Journal: :asia oceania journal of nuclear medicine and biology 0
yasuyuki takahashi department of nuclear medicine technology, gunma prefectural college of health sciences, maebashi, japan masao miyagawa department of radiology, ehime university graduate school of medicine, toon, japan yoshiko nishiyama department of radiology, ehime university graduate school of medicine, toon, japan naoto kawaguchi department of radiology, ehime university graduate school of medicine, toon, japan hayato ishimura department of radiological technology, ehime university hospital, toon, japan teruhito mochizuki department of radiology, ehime university graduate school of medicine, toon, japan

objective(s): the energy resolution of a cadmium-zinc-telluride (czt) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional anger type detector which is 10%. also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. in this study, we used a semiconductor detector and examined the ef...

Journal: :iranian journal of nuclear medicine 0
alireza sadremomtaz department of physics, faculty of science, university of guilan, rasht, iran zeinab telikani department of physics, faculty of science, university of guilan, rasht, iran

introduction: image quality and accuracy of in vivo activity quantification in spect are affected by collimator penetration and scatter components, especially in high energy imaging. these phenomena highly depend on the collimator characteristic and photon energy. the presence of penetrated and scattered photons from collimator in spect images degrades spatial resolution, contrast and image qua...

ژورنال: سنجش و ایمنی پرتو 2018

In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...

Journal: :iranian journal of nuclear medicine 2004
nasrollah jabbari hossein rajabi hassan firoozabadi fereidoon rastgoo nahid yaghoobi

introduction: scatter radiation is one of the major sources of error in nuclear medicine data processing. different methods of scatter correction have been introduced in order to improve the quality of data. however the best method is to avoid recording of scatter photons in acquisition. the only difference between scattered and non-scattered photons is the energy. pulse height analyzer is the ...

Journal: :iranian journal of medical physics 0
ali asghar mowlavi physics department, hakim sabzevari university, sabzevar, iran. international centre for theoretical physics (ictp), associate and federation schemes, medical physics field, trieste, italy.

introduction range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (pet). in this study, geant4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in pet imaging including 11c, 13n, 15o, 18f, 68ga, and 82rb. materials and methods gea...

Journal: :iranian journal of nuclear medicine 2005
ahmad bitarafan rajabi hossein rajabi seyed hasan firoozabadi nahid yaghoobi feridoon rastgoo

introduction: acceptance test is a necessary procedure after spect system installation. the goal of this test is to reveal system's present condition, to compare it with manufacturer's specifications and also as a base for later tests. methods: this study investigated four spect systems in tehran. all of the quality control tests are performed on the basis of nema and iaea recommendations and b...

Ahmad Bitarafan Rajabi Bijan Hashemi Malayeri Fereidoon Rastgoo Hassan Firoozabadi Hossein Rajabi, Nahid Yaghoobi Nasrollah Jabbari

Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...

Ali Asghar Mowlavi, Mohsen Mashayekhi

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

Ahmad Bitarafan Rajabi Feridoon Rastgoo Ghasem Raziee Hossein Rajabi, Mahasti Amoui Nahid Yaghoobi Seyed Hasan Firoozabadi

Introduction: Acceptance test is a necessary procedure after SPECT system installation. The goal of this test is to reveal system's present condition, to compare it with manufacturer's specifications and also as a base for later tests. Methods: This study investigated four SPECT systems in Tehran. All of the quality control tests are performed on the basis of NEMA and IAEA recommendations...