Journal: :Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 2012
Asghar Mesbahi Vahid Jafarzadeh Nahideh Gharehaghaji

BACKGROUND Application of less toxic normoxic polymer gel of N-isopropyl acrylamide (NIPAM) for radiation therapy has been studied in recent years. AIM In the current study the optical and NMR properties of NIPAM were studied for radiation therapy dosimetry application. MATERIALS AND METHODS NIPAM normoxic polymer gel was prepared and irradiated by 9 MV photon beam of a medical linac. The o...

Journal: :iranian journal of medical physics 0
asghar mesbahi medical physics department, faculty of medicine, tabriz university of medical sciences, tabriz, iran. radiation oncology department, imam hospital, tabriz, iran

introduction the purpose of the current study was to determine optical sensitivity of n-isopropyl acrylamide nipam and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (pagat) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. materials and methods nipam and pagat polymer gels with conventional formulations used f...

2017
E Maynard M Hilts

This work assesses the overall reproducibility and accuracy of an x-ray computed tomography (CT) polymer gel dosimetry (PGD) system using a N-isopropylacrylamide (NIPAM) based polymer gel and investigated what effects the use of generic, inter-batch, and intra-batch gel calibration have on dosimetric and spatial accuracy. Overall excellent spatial and dosimetric accuracy was found with this sys...

2016
Kai-Yuan Cheng Ling-Ling Hsieh Cheng-Ting Shih

Polymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this study, the short-term stability within 24 h and feasibility of N-isopropylacrylamide (NIPAM) polyme...

Asghar Mesbahi, Seyed-Salman Zakariaee

Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used f...

A.R. Farajollahi, F. Pak, M. Horsfield, Z. Myabi,

Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...

2011
Timothy Olding Oliver Holmes Paul DeJean Kim B. McAuley Ken Nkongchu Giles Santyr L. John Schreiner

This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM)-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparis...

Journal: :iranian journal of radiation research 0
a.r. farajollahi department of medical physics, faculty of medicine, tabriz university of medical sciences, tabriz, iran f. pak department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran m. horsfield department of cardiovascular sciences, university of leicester, leicester royal infirmary, leicester, uk z. myabi department of radiology, emam reza teaching hospital, tabriz university of medical sciences, tabriz, iran

background: in this study the basic radiation properties of n-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. materials and methods: the nipam gel was prepared and irradiated approximately 2 h after manufacturing. the magnetic resonance (mr) images were made 24 h after irradiation. the nuclear magnetic resonance (nmr) respons...

Seyed Mohammad Mahdi Abtahi Vahid Anaraki

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...