A. Keyvani Borujeni, T. Mahdi,

Abstract: This paper introduces a new numerical method for the analysis of infilled steel frames with hollow clay blocks. This approach is based on the brittle cracking model of ABAQUS. The results of the in-plane calibration analyses obtained with four experimental tests are presented and discussed. The first test was a bare steel frame used as a control specimen. The second was similar to ...

C. Freeda Christy D. Tensing, S. Vincent Sam Jebadurai

Masonry infill has been widely used as building material due to its cost effectiveness and availability.  The failure of these masonry infill walls during the past earthquakes have underscored the importance of ensuring the safety of the infill walls when it is subjected to lateral loads. In-plane and out of plane failures have been observed in many reinforced concrete framed building with maso...

2016
Hongyu Deng Baitao Sun

During the analysis of reinforced concrete structures, the infill wall is usually simplified as a diagonal inclined strut to facilitate finite element modeling calculations. However, the actual seismic damage and single frame-filled wall pushover experimental results show that when the earthquake shear force is huge, the top of the infill wall and the beam–column connections are usually, thus t...

This paper describes the testing of Profiled Steel Sheet Dry Board (PSSDB) load bearing wall system. Experimental tests were conducted on various PSSDB wall samples, with and without infill materials to study its effect on the PSSDB load bearing wall performance. A proprietary profiled steel sheet, Ajiya Cliplock (0.48 mm thick) attached to Cemboard (10 mm thick) on one side, and Cemplank (10 m...

2015
V. Lavanya P. Anuradha Murali Krishna

High raised buildings are vulnerable to the lateral loads caused during natural calamities like earthquakes and cyclones. Lateral loads always affect the stability of structures. The shear walls, which are provided to resist these lateral forces, are often considered undesirable from utility point of view as they come in the way of vehicular movement in the parking area. Methods to evaluate the...

2012
D. S. Lunn S. H. Rizkalla

ABSTRACT: This paper explores the behavior of infill masonry structures strengthened with a new type of Fiber Reinforced Polymer (FRP) strengthening system with high fracture strain know as PET (Polyethylene Teraphthalate) and a new near-surface mounted (NSM) Carbon fiber strengthening system using a cementitious material as the adhesive as compared to a Glass Fiber (GFRP) strengthening system ...

Journal: :مهندسی عمران فردوسی 0
فریبرز ناطقی الهی مسعود خزایی پول

in this paper, nonlinear behavior of composite steel plate shear wall systems, in which steel infill plate is strengthened by fiber reinforced polymer (frp) layers, are experimentally investigated. tests are designed to evaluate the effect of glass-frp layers, layers number of gfrp and orientation of gfrp layers on the stiffness, shear strength, cumulative dissipated energy and other seismic pa...

composite concrete-steel plate shear walls are the most critical resisting structural members that resist lateral and axial loads. This type of wall consisting of two steel faceplates presenting the outer skin, infill concrete and shear connectors which are used to provide the composite action of the steel faceplates with infill concrete in order to increase the strength and to reduce the local...

2013
Vladimir Sigmund Davorin Penava

Original scientific paper Reinforced-concrete (R/C) frames infilled with masonry wall, especially with the presence of an opening, are insufficiently explored structural elements. We have experimentally investigated influence of the opening’s type and position to the lateral response of reinforced-concrete frames with masonry infill. Correction factors, that take into account influence of the o...

2004
Jeffrey W. Berman

This paper describes the prototype design, specimen design, experimental set-up, and experimental results of tests on three light-gauge steel plate shear wall (SPSW) concepts. Prototype light-gauge steel plate shear walls are designed as seismic retrofits for a hospital structure in an area of high seismicity and emphasis is placed on minimizing their impact on the existing framing. Three singl...