نتایج جستجو برای: MRI-based polymer gel dosimetry

تعداد نتایج: 3180930  

Journal: :iranian journal of medical physics 0
m. sedaghat ph.d. student in medical physics, university of sherbrooke, canada. m.h zahmatkesh assistant professor, novin medical radiation institute, tehran, iran. r. jaberi m.sc. in medical physics, cancer institute, imam hospital, tums, tehran, iran. sh. akhalghpoor assistant professor, faculty of medicine, tums & novin medical radiation institute, tehran, iran. m. allahverdi assistant professor, dept. of medical physics, faculty of medicine, tums & cancer institute of imam hospital, tehran, iran.

introduction: despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. in the current work, the feasibility of using a normoxic polymer gel dosimeter named magica has been investigated for use in our clinical brachytherapy applic...

Journal: :iranian journal of radiation research 0
m. gholami department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran d. shahbazi-gahrouei department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran t. allahverdi pourfallah department of biophysics and biochemistry, school of medicine, mazandaran university of medical sciences, sari, iran

background: the human body contains of different tissues and cavities with different physical and radiological properties. most important among these are tissues and cavities that are radiologically different from water, including lungs, sinuses and bones. gel dosimetry provides a unique feature to display dose distributions occurring in clinical radiation therapy in three dimensions. materials...

Journal: :iranian journal of medical physics 0
reza moghadam-drodkhani m.sc. in medical physics, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran nader riyahi-alam professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran abbas takavar professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran kavous firoznia associate professor, radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran peiman hadad associate professor, radiotherapy dept., imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran behrooz rafiee m.sc., radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: the conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. although the polymer gel dosimetry method based on magnetic resonance imaging (mri) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

Ahmad Farahani Behrooz Reafie Hassan Hashemi Leaila Karimi-Afshar Mahmoud Allahverdi, Mohammadreza Ay Morteza Bakhteiari Nader Riahi Alam Tayeb Alahverdi purfallah

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

Abbas Takavar, Behrooz Rafiee Ehsan Mohammadi Kavous Firoznia Morteza Bakhtiary Nader Riyahi-Alam Peiman Hadad Reza Moghadam-Drodkhani Zohre Tizmaghz

Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

A R Montazerabadi A Takavar M H Zahmatkesh M Keshtkar,

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran ghorban safaeian m.sc., in medical physics, mashhad university of medical sciences, mashhad, iran mohammad hosein bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran shahram baiani m.sc., in medical engineering, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran

introduction: the purpose of this work was to study the ability of mri normoxic polymer gel dosimetry for evaluating the dose distribution in hdr brachytherapy of esophagial cancer at imam reza brachytherapy center (mashhad, iran). materials and methods: initially, 2liters of normoxic gel (magic) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

A.H. Barati, H.A. Nedaie, M. Afkhami, M. Yarahmadi, M.H. Zahmatkesh, W. Parwaie,

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

Ghorban Safaeian, Mina Nouri, Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi Shahram Bayani

Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods:  Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...