نتایج جستجو برای: Monte Carlo Simulation Breast Cancer

تعداد نتایج: 1576581  

Journal: :iranian journal of radiation research 0
a. chaparian tehran university of medical sciences, medical physics and biomedical engineering department, tehran, iran m.a. oghabian tehran university of medical sciences, medical physics and biomedical engineering department, tehran, iran v. changizi tehran university of medical sciences, radiology technology department, tehran, iran

background: recently, it has been indicated that x-ray coherent scatter from biological tissues can be used to access signature of tissue. some scientists are interested in studying this effect to get early detection of breast cancer. since experimental methods for optimization are time consuming and expensive, some scientists suggest using simulation. monte carlo (mc) codes are the best option...

A. Chaparian, M.A. Oghabian, V. Changizi,

Background: Recently, it has been indicated that X-ray coherent scatter from biological tissues can be used to access signature of tissue. Some scientists are interested in studying this effect to get early detection of breast cancer. Since experimental methods for optimization are time consuming and expensive, some scientists suggest using simulation. Monte Carlo (MC) codes are the best...

Journal: :iranian journal of medical physics 0
banafsheh zeinali rafsanjani m.sc. of nuclear engineering, medical radiation trends, faculty of mechanical engineering, shiraz university, shiraz, iran. reza faghihi assistant professor of medical radiation, radiation research center, faculty of mechanical engineering, shiraz university, shiraz, iran.

introduction: among different kinds of oral cavity cancers, the frequency of tongue cancer occurrence is more significant. brachytherapy is the most common method to cure tongue cancers. long sources are used in different techniques of tongue brachytherapy. the objective of this study is to asses the dose distribution around long sources, comparing different radioisotopes as brachytherapy sourc...

Dariush Sardari Mahdi Sadeghi, Niloofar Azadegan Seyed Pezhman Shirmardi,

Introduction: The proton beam produced in particle accelerators has an appropriate therapeutic potential. In this research, proton therapy of breast cancer is simulated using the MCNPX code in a MIRD phantom, also the contribution of scattered neutron dose during the proton therapy were calculated for the Heart, Lung and Liver.   Materials and Methods: For si...

Journal: :iranian journal of radiology 0
lida gholamkar department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran ali asghar mowlavi physics department, hakim sabzevari university, sabzevar, iran; international center for theoretical physics (ictp), associate federation scheme, medical physics field, trieste, italy; physics department, hakim sabzevari university, sabzevar, iran. tel: +98-5144012521 mahdi sadeghi radiation application research school, nuclear science and technology research institute, tehran, iran mitra athari department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

conclusion by comparing the results, we saw that w/rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with w/ag and rh/al. moreover, breast thickness and g value have significant effects on mgd. objectives the aim of this study was to determine the average absorbed dose of x-ray radiation in the glandular tissue of the...

Ali Neshasteh-Riz Fereshteh Koosha, Ghazale Mansorian Mostafa Robatjazi, Reza Paydar,

Introduction: One of the treatment choices in breast cancer is Intra operative electron beam radiation therapy (IOERT). Due to high dose delivery in this procedure, shielding disk is used to protect organs at risk (OARs). In this study, we evaluate the OARs dose in the breast IOERT using Monte Carlo simulation with and without shielding disk in RANDO phantom. Material and Methods: Simulation ...

A. Amouheidari, M. Atarod, P. Shokrani,

Background: The aim of this study was to develop and implement a Monte Carlo framework for evaluation of patient specific out-of-field organ equivalent dose (OED). Materials and Methods: Dose calculations were performed using a Monte Carlo-based model of Oncor linac and tomographic phantoms. Monte Carlo simulations were performed using EGSnrc user codes. Dose measurements were performed using r...

Journal: :iranian journal of management studies 2013
hamid shahbandarzadeh khodakaram salimifard reza moghdani

in this paper, the pricing of a european call option on the underlying asset is performed by using a monte carlo method, one of the powerful simulation methods, where the price development of the asset is simulated and value of the claim is computed in terms of an expected value. the proposed approach, applied in monte carlo simulation, is based on the black-scholes equation which generally def...

Journal: :Journal of Physics: Conference Series 2018

Ali Shabestani Monfared, Mohammad Davoudi Mohammad Rahgoshay

Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید