Journal: :energy equipment and systems 0
abbas ketabi department of electrical engineering, university of kashan, kashan, iran sahbasadat rajamand department of electrical engineering, university of kashan, kashan, iran mohammad shahidehpour illinois institute of technology, chicago, usa

microgrids are nowadays used to produce electric energy with more efficiency and advantage. however, the use of microgrids presents some challenges. one of the main problems of the microgrids widely used in electrical power systems is the control of voltage, frequency and load sharing balance among inverter- based distributed generators (dgs) in islanded mode. droop method performance degrades ...

Journal: :International Journal of Electrical and Computer Engineering (IJECE) 2015

2013
A. M Bouzid

The Self Excited Induction Generator (SEIG) is an isolated power source, whose terminal voltage and frequency are controlled by the excitation of capacitance or the load impedance. A new strategy based on an active power filter (APF) for controlling the current and power quality of the self-excited induction generator (SEIG) is also presented in this paper. The proposed active filter proved to ...

2016
G S Mahesh

The harmonic mitigation using shunt active filters are most widely used in industrial and commercial applications. In this paper a Multi-Level Inverter is considered as DSTATCOM to compensate harmonics. The mathematical modeling of the system and design of the controller using synchronous reference frame theory is also presented. The nonlinear load generally known as diode rectifier load and an...

2003
Seyed Hossein Hosseini Mehrdad Tarafdar Haque S. Shahmohammadi

This paper first presents a simple control technique for active filters to compensate current harmonics and reactive power of nonlinear loads. This method is usable for both single –phase and three –phase systems. Then a new method for load balancing and reactive power compensation for unbalanced sinusoidal load currents is presented. Finally by combination of two methods an active filter contr...

2016
R. MURALI SACHITHANANDAM

The application of power semiconductor devices in the area of power electronics and power system are the key factors which kindle the power quality problems particularly the harmonics, burden of reactive power and neutral current due to unbalance. The above citied power quality problems are predominant due to wide usage of 1-φ / 3-φ , linear and nonlinear loads which are fed from three phase fo...

2015
Harmeet Singh Jasvir Singh

ABSTRACT The control of renewable energy in electrical power system is investigated with the integration. The generation of electrical energy from renewable energy sources is fed to the grid after conversion by DC/AC converter. For compensation of current unbalance, load reactive power demand, load neutral current and load current harmonics etc, shunt active power filter are used. With the comb...

Low voltage microgrids including sensitive loads often face unbalanced load conditions. Therefore, a compensation procedure should be carried out in order to balance and restore sensitive load’s voltage. In this paper, an effective voltage control strategy has been proposed for the autonomous operation of microgrids, under unbalanced load conditions.  The proposed strategy balances single-phase...

Abbas Ketabi Mohammad Shahidehpour Sahbasadat Rajamand

Microgrids are nowadays used to produce electric energy with more efficiency and advantage. However, the use of microgrids presents some challenges. One of the main problems of the microgrids widely used in electrical power systems is the control of voltage, frequency and load sharing balance among inverter- based distributed generators (DGs) in islanded mode. Droop method performance degra...