نتایج جستجو برای: Osteosynthesis

تعداد نتایج: 2179  

Journal: :Collegium antropologicum 2009
Vladimir Sisljagić Savo Jovanović Tomislav Mrcela Radivoje Radić Tatjana Belovari

In surgery of fractured long bones, a patient suffering from osteoporosis represents constant challenge to a surgeon and applied material and instruments that need to destroy as little as possible of an already damaged bone. One potential way of increasing the contact surface between the implants and osteoporotic bone is injection of bone cement (methyl-metacrilat, Palakos) into a prepared scre...

2017
Feng-Jen Tseng Wei-Tso Chia Ru-Yu Pan Leou-Chyr Lin Hsian-Chung Shen Chih-Hung Wang Jia-Fwu Shyu Ching-Feng Weng

BACKGROUND This meta-analysis compared clinical outcomes of arthroplasty vs. osteosynthesis for displaced femoral neck fractures. METHODS Meta-analysis was performed on the difference in revision rate and overall mortality between participants undergoing osteosynthesis vs. total hip arthroplasty (THA), osteosynthesis vs. hemiarthroplasty (HA), or THA vs. HA. RESULTS Pooled direct and indire...

Journal: :Acta orthopaedica Belgica 2008
Jan Robert Tarnowski Kim Holck

In this case report, we show how it is possible to perform osteosynthesis using minimal invasive techniques instead of conventional methods. In this instance the osteosynthesis was performed on a patient in poor general condition who had presented a periprosthetic fracture of the proximal femur. For the osteosynthesis the Less invasive Stabilization System intended for distal femur fractures wa...

Journal: :Orthopedics 2013
Kejian Lian Lei Wang Dasheng Lin Zhiwen Chen

Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23...

Journal: :journal of dentistry, tehran university of medical sciences 0
h. mohajerani assistant professor, department of oral and maxillofacial surgery, school of dentistry, shahid behes m. mehdizadeh oral & maxillofacial surgeon, private practice a. khalighi sigaroodi postgraduate student, department of oral and maxillofacial surgery, school of dentistry, shahid behe

objective: the aim of this study was to assess skeletal relapse in patients who underwent mandibular setback by bilateral sagittal split ramus osteotomy (bssro) and osteosynthesis wiring techniques. materials and methods: in this semi-experimental study, 10 patients (8 women, 2 men) with 3-8 millimeters overjet underwent mandibular setback with bssro, osteosynthesis wiring and inter maxillary f...

2015
Saravana Kumar Waikhom Arvind

The management of trauma has evolved greatly over the past many years. Various bone plating have been introduced for stable fixation of mandibular fractures. The present concept of treating mandibular fractures is with non-compression mini plates which relieves the patient from a hazardous intermaxillary fixation with wires and gives better stability and osteosynthesis. When placed along the Ch...

Journal: :Journal of Ayub Medical College, Abbottabad : JAMC 2012
Assad Abbas Iffat Batool Syed Hasnain Abbas Iram Abbas

OBJECTIVE The purpose of this study was to compare the outcome of wire osteosynthesis with bone plating in the management of zygomatic complex (ZMC) fractures. The rationale was to enable the oral and maxillofacial surgeon to select either of the treatment procedure with confidence. METHODS In this quasi experimental study, Sixty five patients of ZMC fractures were randomly allocated in group...

Journal: :Pathobiology : journal of immunopathology, molecular and cellular biology 2013
Paul Schumann Daniel Lindhorst Maximilian E H Wagner Alexander Schramm Nils-Claudius Gellrich Martin Rücker

Since introduction to the clinics in the 1990s, resorbable osteosynthesis systems have undergone extensive improvements in order to establish their use as a standard treatment, especially in craniomaxillofacial surgery. However, the development of osteosynthesis systems made of poly(α-hydroxy acid) polymers has been hindered by the lack of information on the mechanical properties and biocompati...

Journal: :trauma monthly 0
javad yazdani department of oral and maxillofacial surgery, tabriz university of medical sciences, tabriz, ir iran kourosh taheri talesh department of oral and maxillofacial surgery, azad university of medical sciences, tehran, ir iran mohammad hosein kalantar motamedi trauma research center, baqiyatallah university of medical sciences, tehran, ir iran; trauma research center, baqiyatallah university of medical sciences, tehran, ir iran. tel.: +98-9121937154, fax: +98-2188053766 reza khorshidi department of oral and maxillofacial surgery, tabriz university of medical sciences, tabriz, ir iran sasan fekri department of oral and maxillofacial surgery, yazd university of medical sciences,yazd, ir iran saeed hajmohammadi department of oral and maxillofacial surgery, tabriz university of medical sciences, tabriz, ir iran

conclusions in this study, use of one miniplate or two miniplates for treatment of favorable mandibular angle fractures was associated with a similar incidence of complications. thus, it seems that the use of two miniplates in this setting may not be warranted, nor cost-efficient. results in the single miniplate group, 25 patients showed lip numbness associated with surgery (55.6%), 22 patients...

Journal: :trauma monthly 0
abolfazl bagherifard bone and joint reconstruction research center, shafa orthopedic hospital, iran university of medical sciences, tehran, ir iran mahmoud jabalameli bone and joint reconstruction research center, shafa orthopedic hospital, iran university of medical sciences, tehran, ir iran hosseinali hadi bone and joint reconstruction research center, shafa orthopedic hospital, iran university of medical sciences, tehran, ir iran mohammad rahbar bone and joint reconstruction research center, shafa orthopedic hospital, iran university of medical sciences, tehran, ir iran mohammadreza minator sajjadi taleghani hospital research development unit, shahid beheshti university of medical sciences, tehran, ir iran; taleghani hospital research development unit, shahid beheshti university of medical sciences, tehran, ir iran. tel: +98-2133542008, fax: +98-2133542020 ali jahansouz bone and joint reconstruction research center, shafa orthopedic hospital, iran university of medical sciences, tehran, ir iran

conclusions in this case series study, the fixation of different types of tibial plateau fractures with 3.5 mm simple non-locking and non-precontoured plates was associated with acceptable clinical, functional, and radiographic outcomes. based on the advantages and costs of these plates, the authors recommend using 3.5 mm simple plates for different types of tibial plateau fractures. results th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید