نتایج جستجو برای: Patient Specific QA

تعداد نتایج: 1683295  

Journal: :Journal of Applied Clinical Medical Physics 2014

Abdolazim Sedighi Mohammad Hadi Gholami, Mohammad Mohammadi, Ramin Jaberi

Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...

Journal: :journal of biomedical physics and engineering 0
s r mahdavi k keshavarzi e davani

objectives: the aim of this study was to verify the treatment planning systems (tpss). the next aim was to validate imsure qa software for patient-specific qa in radiotherapy clinics.  material and methods: we used imsure qa software (standard imaging, v 3.5) for verification of 92 non-imrt plans (540 fields) in 10 radiotherapy clinics. to validate the imsure, dose measurement was performed in ...

2014
Elizabeth M. McKenzie Peter A. Balter Francesco C. Stingo Jimmy Jones David S. Followill Stephen F. Kry

The purpose of this study was to determine the reproducibility of patient-specific, intensity-modulated radiation therapy (IMRT) quality assurance (QA) results in a clinical setting. Six clinical patient plans were delivered to a variety of devices and analyses, including 1) radiographic film; 2) ion chamber; 3) 2D diode array delivered and analyzed in three different configurations (AP deliver...

B. Gowri, C. Anu Radha, V. Ramasubramanian,

Background: External beam radiotherapy and brachytherapy plays a vital role in the management of cancer cervix.  High dose rate brachytherapy is being presently used worldwide for the brachytherapy applications. At present, 2-Dimensional linear array detectors   are the most common QA tool used for pretreatment patient specific quality assurance in external beam radiotherapy alon...

Journal: :Technology in Cancer Research & Treatment 2014

2017
Ji Woon Yea Jae Won Park Sung Kyu Kim Dong Youn Kim Jae Gu Kim Chan Young Seo Won Hyo Jeong Man Youl Jeong Se An Oh

This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Contoured left and right head phantoms were converted from DICOM to STL format. Fused deposition modeling (FDM) was used to construct an anthropomorphic patient-specific head phantom with a 3D printer...

Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab-wooden dust (pine)-SP34 slab (SWS) heterogeneous phantom.  Materials and Methods: Th...

2017
Satoshi Nakamura Hiroyuki Okamoto Akihisa Wakita Rei Umezawa Kana Takahashi Koji Inaba Naoya Murakami Toru Kato Hiroshi Igaki Yoshinori Ito Yoshihisa Abe Jun Itami

There are many reports concerning patient-specific quality assurance (QA) for intensity-modulated radiation therapy (IMRT). However, reports about the statistical results of QA are lacking. Management methods for the results of the QA are needed, even though we have the ESTRO group recommendation that a tolerance limit of 1.96 standard deviation (SD) be established in each institution. The purp...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید