نتایج جستجو برای: Radial Dose Function

تعداد نتایج: 1533152  

Journal: :iranian journal of radiation research 0
m. zehtabian radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran r. faghihi radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran s. sina radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran

background: iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. dosimetric parameters of brachytherapy sources should be determined according to aapm tg-43u1 recommendations before clinical use. monte carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. materials and methods: dosimetric parameters (dos...

Journal: :iranian journal of medical physics 0
vahid lohrabian educational development center, ilam university of medical sciences, ilam, iran

introduction low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. dosimetric characteristics of a new irseed 125i brachytherapy source have been determined using the lif thermoluminescent dosimeter (tld) chips. materials and methods dose rate constant, radial dose function, and anisotropy function around the irseed 125i so...

ژورنال: سنجش و ایمنی پرتو 2019

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

Behroz Ghozati Hamid Reza Baghani Hosein Pourbeigi Mahmoud Reza Aghamiri Shahab Sheibani Vahid Lohrabian,

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

Hossein Tavakoli-Anbaran, Ome Leila Ahmadi

Introduction: The commercial 252Cf sources are too large in size and clinical applications of neutron brachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, c...

Hossein Tavakoli-Anbaran, Ome Leila Ahmadi

 Introduction:The commercial 252Cf sources are too large in size and clinical applications of neutronbrachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, cal...

Journal: :iranian journal of medical physics 0
fatemeh lotfalizadeh department of ray-medical engineering, shiraz university, shiraz, iran mehrnoosh karimipourfard department of ray-medical engineering, shiraz university, shiraz, iran bentolhoda amanat department of physics, payame noor university, tehran, iran mehdi zehtabian department of ray-medical engineering, shiraz university, shiraz, iran

introduction based on task group no. 43 (tg-43u1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. the experimental determination of tg-43 parameters is usually performed in water-equivalent solid phantoms. the purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. materials and methods t...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی شاهرود - دانشکده فیزیک 1391

براکی تراپی، روشی در پرتو درمانی است که در آن از چشمه های رادیواکتیو ویژه ای در فاصله ی نزدیک، در تماس یا کاشت در تومور، برای درمان استفاده می شود به طوری که بافت آسیب دیده بیشترین دز را دریافت کرده در حالی که به بافت های سالم اطراف آن آسیب کمتری برسد. چشمه ها ی 103pd و 125i به طور گسترده در درمان تومورهای بدخیم استفاده می شوند. در سال 1986 چشمه 103pdبه عنوان یک انتخاب مناسب برای جایگزینی چشم...

Ali. S. Meigooni Bentolhoda Amanat, Fatemeh Lotfalizadeh, Mehdi Zehtabian, Mehrnoosh Karimipourfard, Neda Zaker Sedigheh Sina

Introduction Based on Task Group No. 43 (TG-43U1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods T...

M. Zehtabian, R. Faghihi, S. Sina,

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید