نتایج جستجو برای: Steel Post-Tensioned Connections

تعداد نتایج: 546546  

Ahmadreza Torabipour Mahmoudreza Shiravand,

Due to lack of the proper and well behavior of steel moment-resisting connections subjected to the great and major earthquakes, excessive researches have been conducted to mitigate the damages on the primary elements and connections. Therefore, elimination of residual drift and increasing the plastic rotation capacity for the connectors in the panel zone are required. The main purpose of this s...

2015
Jean-Paul Lebet

The mechanical response of post-tensioned glass beams is explored in this paper. This is done through bending experiments on post-tensioned glass beam specimens with either mechanically anchored or adhesively bonded steel tendons by which a beneficial pre-stress is inflicted on the glass beams. In addition, reference beams with identical geometry but without tendons are tested. From the results...

2015

Since, it is essential to provide homeless people by the earthquake with safe, habitable accommodation repairing medium and slight levels of damage at the connection parts should be undertaken. In order to prove that a repaired connection was sufficiently strong, a precast beam to column post tensioned connection was tested in three phases. In phase one, the middle level damage was observed at ...

Following the Northridge earthquake of 1994, a significant number of steel moment resisting structural systems were damaged. Several studies have been conducted to improve the seismic performance of steel structures and specially their beam-to-column connections. One of the proposed connections for special moment-resisting frames included AISC-358 is Kaiser bolted bracket moment connection, bri...

Journal: :Proceedings of National Aviation University 2009

2015
M. E. Soto - López I. Gaxiola - Avendaño A. Reyes - Salazar E. Bojórquez S. E. Ruiz

Abstract—The seismic responses of steel buildings with semirigid post-tensioned connections (PC) are estimated and compared with those of steel buildings with typical rigid (welded) connections (RC). The comparison is made in terms of global and local response parameters. The results indicate that the seismic responses in terms of interstory shears, roof displacements, axial load and bending mo...

Journal: : 2022

This article evaluates and compares the punching shear behaviour of unbonded prestressed concrete (UPC) slab - concrete-filled steel tube (CFT) column connections/joints with that reinforced (RC) connection – CFT connections. The experimental program was carried out on five large-sized samples, including three UPC samples two RC samples. Steel plate details were utilised to increase bond betwee...

Journal: :Journal of the Computational Structural Engineering Institute of Korea 2020

The application of external post-tensioned steel bars as an effective way to strengthen an existing bridge has been so far used in many different countries. In recent decades, however, they have been replaced by bars made from Carbon Fiber Reinforced Polymer (CFRP), as a material with high tensile strength and corrosion resistance, to address several concerns with steel bars such as their appli...