Hajareh Ghaderzadeh Hamed Ghaffari Mahdieh Afkhami, Mohammad Haghparast Seyed Rabi Mahdavi

Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...

Journal: :Medical physics 2012
K Poels T Depuydt D Verellen M De Ridder

PURPOSE to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. METHODS A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondence model. The DT prototype software allowed the detailed logging of all appli...

Journal: :iranian journal of radiation research 0
s. r. mahdavi medical physics department of iran university of medical sciences, tehran, iran e. jazayeri gharehbagh department of radiology and radiotherapy technology, school of allied health sciences, tehran university of medical sciences, tehran, iran b. mofid 3radiotherapy department of shahid beheshti university of medical sciences, tehran, iran a. h. jafari research center of biomedical technology and robotics, tehran university of medial sciences, tehran, iran a. r. nikoofar radiotherapy department of iran university of medical sciences, tehran, iran

background: to correct patient positioning errors (setup errors) during prostate cancer treatment using epid and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. materials and methods: fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field imrt planning technique. the p...

Journal: :Clinical oncology (Royal College of Radiologists (Great Britain)) 2010
M S Zaghloul A G Mousa E Eldebawy E Attalla H Shafik S Ezzat

AIM To compare the accuracy of radiotherapy set-up using an electronic portal imaging device (EPID) versus megavoltage cone beam computed tomography (MV-CBCT) in paediatric patients. MATERIALS AND METHODS In total, 204 pairs of EPID and MV-CBCT were carried out for 72 patients in the first 3 treatment days and weekly thereafter. RESULTS For the whole group, the mean systematic EPID set-up e...

Journal: :iranian journal of pathology 2006
hossein ayatollahi tayebeh kianoush mohammad khajeh daluee

background and objectives: for total analytical error, imprecision (sd) and bias, performance goals for laboratory tests have most often been developed. a total analytical error goal requires that the combination of errors from all sources (random and systematic errors) be within some acceptable limit. materials and methods: fifty vials of sodium and potassium standards (sandos company) were ch...

2014
Arjunan Manikandan Biplab Sarkar Maitreyee Nandy Chandra Sekaran Sureka Michael S. Gossman Nadendla Sujatha Vivek Thirupathur Rajendran

The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an electronic portal imaging device and an ion chamber array. Each plan was copied...

Hossein Ayatollahi, Mohammad Khajeh Daluee Tayebeh Kianoush

Background and Objectives: For total analytical error, imprecision (SD) and bias, performance goals for laboratory tests have most often been developed. A total analytical error goal requires that the combination of errors from all sources (random and systematic errors) be within some acceptable limit. M...

2017
Gerben R. Borst

Purpose: Kilovoltage cone-beam computed tomography (CBCT) has been developed to provide accurate soft-tissue and bony setup information. We evaluated clinical CBCT setup data and compared CBCT measurements with electronic portal imaging device (EPID) images. Material and Methods: The setup error for CBCT scans at the treatment unit relative to the planning CT was measured for 62 patients (524 s...

2016
Todsaporn Fuangrod Peter B. Greer Henry C. Woodruff John Simpson Shashank Bhatia Benjamin Zwan Timothy A. vanBeek Boyd M.C. McCurdy Richard H. Middleton

PURPOSE The aim of this study is to investigate the performance and limitations of a real-time transit electronic portal imaging device (EPID) dosimetry system for error detection during dynamic intensity modulated radiation therapy (IMRT) treatment delivery. Sites studied are prostate, head and neck (HN), and rectal cancer treatments. METHODS The system compares measured cumulative transit E...