Maziar Babaei Sajad Bagheri Zahra Moravej

This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10µs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and pro...

Maziar Babaei Sajad Bagheri Zahra Moravej,

This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10μs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and problem...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شهید چمران اهواز - دانشکده مهندسی علوم آب 1393

drought is transient phenomenon , slow , repetitive and integral part of the climate of each region. drought begins with a substantial reduction in precipitation over the long-term average rainfall and over time, reduced soil moisture and surface and ground water resources will continue to decrease. this phenomenon is the most important in bakhtegan basin because of its importance in strategic ...

2007
E. Petrache A. Phillips

The low-frequency methods used by most utilities nowadays for measuring the resistance of transmission line ground electrodes are inaccurate or cannot be applied when overhead groundwires are connected to the towers. Moreover, many of them are costly and time consuming. This paper proposes and compares two new methods for evaluating the transient impedance of transmission line towers. Both meth...

2014
Zhang Xiaoqing

A circuit model is proposed in this paper for calculating the transient potential rise on the wind turbine struck by lightning. The model integrates the blade, sliding contact site, and tower and grounding system of the wind turbine into an equivalent circuit. The lightning current path from the attachment point to the ground can be fully described by the equivalent circuit. The transient poten...

In this paper, the effect of ocean-land mixed propagation path on the lightning performance of grounding rods is investigated. This effect is focused on two problems. The first is extracting exact equivalent circuit of grounding rods in the presence of oceans. The equivalent circuit can be used in transient analysis of power systems in the neighboring oceans. In the second one, this effect on t...

2015
M. G. Unde B. E. Kushare

During ground faults, fault current flows in the ground which results in potential gradient and ground potential rise (GPR). The potential gradient affects the safety of operating person due to step and touch voltage and GPR affects the insulation of protective devices and control cables. The potential gradient and GPR are the functions of ground electrode geometry. In this paper, performance a...