نتایج جستجو برای: Transmittance

تعداد نتایج: 4645  

Journal: :Journal of dental research 1980
R H Brodbelt W J O'Brien P L Fan

The translucency of comparable shades of five dental porcelains was determined. Both direct transmittance and total transmittance were measured at wavelengths of 400-700 nm. For 1 mm of porcelain, the values for direct transmittance were low and averaged 0.13 percent, whereas the values for total transmittance averaged 26.8 percent. Transmittance increased with increasing incident wavelength. T...

2007
Lilik Hasanah Khairurrijal Mikrajuddin Abdullah Toto Winata

An analytic expression of transmittance based on the Airy wavefunctions approach has been derived for an electron through an anisotropic heterostructure with an applied voltage to the barrier of the heterostructure. The Si(110)|Si0.5Ge0.5|Si(110) heterostructure was used to examine the analytic expression. In order to evaluate the Airy wavefunctions approach, the transfer matrix method, which i...

Journal: :Journal of the Optical Society of America. A, Optics, image science, and vision 2006
Mathieu Hébert Roger David Hersch

We propose a spectral prediction model for predicting the reflectance and transmittance of recto-verso halftone prints. A recto-verso halftone print is modeled as a diffusing substrate surrounded by two inked interfaces in contact with air (or with another medium). The interaction of light with the print comprises three components: (a) the attenuation of the incident light penetrating the print...

2014
Hyung-Jin Choi Jin-Seok Choi Byeong-Ju Park Ji-Ho Eom So-Young Heo Min-Wook Jung Ki-Seok An Soon-Gil Yoon

Homogeneously distributed zinc nanoparticles (NPs) on the glass substrate were investigated for the transmittance, mechanical durability, and antibacterial effect. The buffered Ti NPs between Zn NPs and glass substrate were studied for an enhancement of the transmittance and mechanical endurance. The Ti NPs buffered Zn NPs showed a high transmittance of approximately 91.5% (at a wavelength of 5...

Journal: :NeuroImage 2003
Eva Syková Lýdia Vargová Sárka Kubinová Pavla Jendelová Alexandr Chvátal

Changes in intrinsic optical signals could be related to cell swelling; however, the evidence is not compelling. We measured light transmittance, ECS volume fraction (alpha), and extracellular K+ in rat spinal cord slices during electrical stimulation and the application of elevated potassium, NMDA, or anisoosmotic solutions. Dorsal root stimulation (10 Hz/1 min) induced an elevation in extrace...

2000
A. Geranios E. Fokitis A. Petridis M. Vassiliou

An experimental setup and procedure for accurate transmittance measurements of candidate filters for the Auger Fluorescence Detector is presented. For this check, we used the Hitachi U-2000 double-beam spectrophotometer (Sph) of the Chemical Department of the University of Athens (UoA). After the calibration of the Sph, we are able to observe transmittance deviations over the area of the filter...

In this paper the transmittance of metal-insulator-metal (MIM) waveguides containing semi-circular ring shaped and rectangular ring shaped grooves are investigated. By varying groove parameters their effects on the transmittance of the MIM waveguides are investigated. The results show that the transmittance spectra of the waveguides have maximum and minimum points, and by using appropriate para...

Journal: :Applied optics 1999
M Takeya N Tsumura H Haneishi Y Miyake

Transmittance spectra of fungi were estimated from seven-band optical micrographs. An optical microscope adjusted with a single-chip CCD camera with seven band filters was used for image acquisition. The Wiener method was applied to estimate the transmittance spectra of five species that belong to one genus of fungi. The Wiener estimation operator was calculated from transmittance spectra of 16...

2007

Optical glasses are optimized to provide excellent transmittance throughout the total visible range from 400 to 800 nm. Usually the transmittance range spreads also into the near UV and IR regions. As a general trend lowest refractive index glasses show high transmittance far down to short wavelengths in the UV. Going to higher index glasses the UV absorption edge moves closer to the visible ra...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید