نتایج جستجو برای: U-bend, 90° elbow
تعداد نتایج: 390038 فیلتر نتایج به سال:
computational fluid dynamics (cfd) simulations of gas-solid flow through a positive low-pressure pneumatic conveyor were performed using eulerian-eulerian framework. pressure drop in pneumatic conveying pipelines, creation and destruction of plugs along the horizontal and vertical pipes, effect of 90° elbows and u-bends on cross-section concentrations, and rope formation and dispersion were num...
This paper presents a numerical study of local mass transfer coefficients in a 90° bend using the RNG version of k–e model to include the influence of curvature on the turbulent transport. Simulations were performed for flow through a 90°, 3-D bend for Reynolds numbers of 13500, 90000, and 390000, Schmidt numbers of 2.53 and 700 and curvature ratios of 1.5, 2, and 2.5. The differences betwe...
this paper presents a numerical study of local mass transfer coefficients in a 90° bend using the rng version of k–e model to include the influence of curvature on the turbulent transport. simulations were performed for flow through a 90°, 3-d bend for reynolds numbers of 13500, 90000, and 390000, schmidt numbers of 2.53 and 700 and curvature ratios of 1.5, 2, and 2.5. the differences between t...
JCO/FEBRUARY 2010 © 2010 JCO, Inc. T venerable Hawley retainer has been basically unaltered in form and application since its introduction to the specialty nearly 100 years ago.1 To add to its utility, we suggest a modification of the retentive clasping mechanism. Although we prefer to use ball clasps rather than Adams clasps because of their sturdiness and simplicity, they are shorter and thus...
Computational Fluid Dynamics (CFD) simulations of gas-solid flow through a positive low-pressure pneumatic conveyor were performed using Eulerian-Eulerian framework. Pressure drop in pneumatic conveying pipelines, creation and destruction of plugs along the horizontal and vertical pipes, effect of 90° elbows and U-bends on cross-section concentrations, and rope formation and dispersion were...
Electrochemical impedance spectroscopy (EIS) was used to detect stress corrosion cracking (SCC) in stainless steel 304 alloy exposed to an aqueous environment at 120 °C. Stainless steel 304 alloy as u-bend was tested in the solution that contains 40 weight percent of magnesium chloride. U-bended samples were prepared according to ASTM G30. EIS measurements were always performed simultaneously o...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید