نتایج جستجو برای: axial compression

تعداد نتایج: 135906  

2015
Yujun Qi Wei Xiong Weiqing Liu Hai Fang Weidong Lu Warren Batchelor

The plate of a pultruded fiber-reinforced polymer or fiber-reinforced plastic (FRP) profile produced via a pultrusion process is likely to undergo local buckling and cracking along the fiber direction under an external load. In this study, we constructed a pultruded glass-fiber-reinforced polymer-light wood composite (PGWC) profile to explore its mechanical performance. A rectangular cross-sect...

2014
Sebastian Kuhn Philipp Appelmann Dorothea Mehler Philip Pairon Pol M Rommens

BACKGROUND Currently, antegrade intramedullary nailing and minimally invasive plate osteosynthesis (MIPO) represent the main surgical alternatives in distal tibial fractures. However, neither choice is optimal for all bony and soft tissue injuries. The Retrograde Tibial Nail (RTN) is a small-caliber prototype implant, which is introduced through a 2-cm-long incision at the tip of the medial mal...

2012
B K Thakkar

Design of shear walls is a complex procedure, especially if the cross section of the shear wall is not regular in shape. Shear walls are usually treated like cantilevers fixed at the foundation level. Normally, lift wells are designed as shear walls. The design of shear walls takes horizontal forces into account by shear and bending. Design for shear in the walls can be managed by computing the...

Journal: :Tissue engineering. Part A 2018
Le W Huwe Gurdeep K Sullan Jerry C Hu Kyriacos A Athanasiou

Generating neocartilage with suitable mechanical integrity from a cell source that can circumvent chondrocyte scarcity is indispensable for articular cartilage regeneration strategies. Costal chondrocytes of the rib eliminate donor site morbidity in the articular joint, but it remains unclear how neocartilage formed from these cells responds to mechanical loading, especially if the intent is to...

2013
Ahmet KARAKASLI Berivan CECEN Orcun TAYLAN Hasan HAVITCIOGLU

To investigate the effect of PLIF and after rigid fixation on adjacent segment and subjacent mechanical instability moreover under loading adjacent and subjacent segment mechanical behavior. Eleven fresh-frozen lamb lumbar spines (Sacrum-T12) were loaded, in axial, flexion-extension, right-left bending directions. All specimens were tested intact and after implantation with posterior pedicle sc...

2016
Jordi Tomás-Hernández

Pilon fractures are distal tibia end fractures affecting the weight-bearing articular surface. They represent around 1% of all lower extremity fractures, and are more common in males between 35 and 40 years of age.1 Such injuries may be caused by highor low-energy mechanisms. Axial compression injuries where the talus impacts on the distal articular surface, causing implosion of the tibial plaf...

2016
Alexandra Lanièce David Brauge Aurélien Laville Wafa Skalli Sébastien Laporte

The purpose of this study was to identify cervical spine morphologies at risk in rugby games. A parameterized osteoarticular finite element model of the cervical spine modeled 17 subjects under three different loadings, each being representative of rugby game phases: scrum (unconstrained axial compression), tackle (full-constraint axial compression) and collapsing scrum (hyperflexion). Stress a...

2013
Jianming Liu

In this paper, a new type of steel-concrete composite member, concrete-filled core steel tube with outer angle steel plank reinforced concrete stub column, is proposed and a series of nonlinear 3D(three-dimensional) full-range numerical calculations under axial compression are carried out, some important factors are analyzed, such as the strength of the concrete, the steel tube and the angle st...

2017
B. F. H. Ang J. Y. Chen A. K. S. Yew S. K. Chua S. M. Chou S. L. Chia J. S. B. Koh T. S. Howe

OBJECTIVES External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised locking compression plate is a low profile alternative. However, the biomechanical differences have not been assessed. The objective of this study was to evaluate th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید