نتایج جستجو برای: cannulated screw

تعداد نتایج: 18705  

Journal: :Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca 2015
Y Imren V Gurkan K Bilsel E E Desteli M Tuna C Gurcan I Tuncay C Sen

PURPOSE OF THE STUDY The objective of this study was to establish relative fixation strengths of proximal femoral nail (PFN), dynamic hip screw (DHS), monolateral external fixator (EF), and cannulated screw (CS) in basicervical hip fracture model. MATERIAL AND METHODS The study involved four groups of implanted composite proximal femoral synthetic bones of eight specimens per group; nailing wit...

2014
N. Ferreira L. C. Marais

Bicondylar tibial plateau fractures are serious injuries to a major weight-bearing joint. These injuries are often associated with severe soft tissue injuries that complicate surgical management. We reviewed 54 consecutive patients who sustained bicondylar tibial plateau fractures that were treated with limited open reduction and cannulated screw fixation combined with fine-wire circular extern...

2014
Metin Uzun Fikri Erkal Bilen Levent Eralp

OBJECTIVES The aim of the treatment of tibial plateau fractures is to obtain a pain-free and fully functional knee with closed reduction, percutaneous cannulated screw fixation and hexapodal external fixator reconstruction for high energy compound upper tibial fractures. METHODS Patients with comminuted tibial plateau fractures underwent closed reduction, percutaneous fixation with cannulated...

2010
Maya E. Pring Mark Adamczyk Harish S. Hosalkar Tracey P. Bastrom C. Douglas Wallace Peter O. Newton

Purpose In situ fixation for mild to moderate slipped capital femoral epiphysis (SCFE) remains an acceptable treatment methodology in most centers. Satisfactory fixation results have been reported with the procedure using either the fracture table or radiolucent table, both of which allow the hip to be imaged during the procedure. The position of the pin within the center of the femoral head is...

Journal: :Journal of orthopaedic surgery 2015
Harun Mutlu Serhat Mutlu

PURPOSE To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. METHODS 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55º and 63º (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated s...

2017
Nikhil Verma M.P. Singh Rehan Ul-Haq Rajesh K. Rajnish Rahul Anshuman

PURPOSE The aim of present study is to evaluate the outcome of bone marrow instillation at the fracture site in fracture of intracapsular neck femur treated by head preserving surgery. METHODS This study included 32 patients of age group 18-50 years with closed fracture of intracapsular neck femur. Patients were randomized into two groups as per the plan generated via www.randomization.com. T...

2017
Avijit Basak Dibyendu Biswas

Background: Intertrochanteric Femur fracture is common in elderly patient with co-morbidity Aims & Objectives: Clinico-radiological evaluation of results of Ender’s nail and cannulated cancellous screw fixation in case of intertrochanteric fracture of femur in elderly patient with preexisting comorbid condition, and functional recovery in those patients. Results: The patients mainly belong to e...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید