نتایج جستجو برای: cannulated screw

تعداد نتایج: 18705  

2011
Tamer Orief Sharaf Bin-Nafisah Khaled Almusrea Mohamed Alfawareh

The preferred treatment of a type II odontoid fracture is anterior odontoid screw fixation to preserve the cervical spine range of movement. This case report describes an unusual complication of guidewire breakage during anterior odontoid cannulated screw fixation for a 52-year-old patient who presented with a type II odontoid fracture after a motor vehicle accident. The distal segment of the g...

Journal: :Acta orthopaedica Belgica 2009
Bhushan Sabnis Ivan Brenkel David Chesney Ian Weir

Cannulated AO screws are commonly used for fracture fixation. Mechanical failure of screws has been well reported but this was mainly breakage of the screw head during removal. We report an unusual mode of failure of an AO self drilling cannulated screw which we have not previously experienced, where the screw threads were found to be unravelled during insertion. We also suggest the way to reco...

2011
Yun Tian Fang Zhou Hongquan Ji Zhishan Zhang Yan Guo

BACKGROUND Although the modified tension band technique (eg, tension band supplemented by longitudinal Kirschner wires) has long been the mainstay for fixation of transverse fractures of the patella, it has shortcomings, such as bad reduction, loosening of implants, and skin irritation. QUESTIONS/PURPOSES We conducted a retrospective comparison of the modified tension band technique and the t...

Journal: :Orthopedics 2013
Shan-Wei Yang Shyh Ming Kuo Shwu Jen Chang Tian-Shiang Su Hsiang-Ho Chen Jenn-Huei Renn Ting-Sheng Lin

The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking ...

2011
Lih-Huei Chen Ching-Lung Tai De-Mei Lee Po-Liang Lai Yen-Chen Lee Chi-Chien Niu Wen-Jer Chen

BACKGROUND Pedicle screws with PMMA cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques, namely solid screws with retrograde cement pre-filling versus cannulated screws with cement injection through perforation, remains unknown. This study aimed t...

2017
Haolin Sun Chun Liu Huiling Liu Yanjie Bai Zheng Zhang Xuwen Li Chunde Li Huilin Yang Lei Yang

Polymethyl methacrylate (PMMA)-augmented cannulated pedicle-screw fixation has been routinely performed for the surgical treatment of lumbar degenerative diseases. Despite its satisfactory clinical outcomes and prevalence, problems and complications associated with high-strength, stiff, and nondegradable PMMA have largely hindered the long-term efficacy and safety of pedicle-screw fixation in o...

2013
Caroline M Blakey Michael Rennison Stephen P Guy Paul M Sutton

BACKGROUND A novel method of fixation has been described for the treatment of pure depression fractures of the lateral tibial plateau. Fracture fragments are elevated through a reamed transtibial tunnel. An interference screw is then passed into the tunnel to buttress fracture fragments from beneath. This method of fixation has perceived benefits but there have been no studies to demonstrate th...

2015
Feng Yao Yu He Hebu Qian Dongsheng Zhou Qinghu Li

The intention of this study was to compare the biomechanical characteristics using 5 internal fixation methods used clinically to stabilize a pubic symphysis diastasis (PSD, Tile type B1).A 3-dimensional finite element model of PSD was simulated using 5 implants, including single superior plate (Single-Plate), superior and anterior plate (Dual-Plate), single cannulated screw (Single-Screw), cro...

2009
Ching-Lung Tai Lih-Huei Chen Po-Liang Lai

INTRODUCTION Pedicle screw fixation in a severely osteoporotic spine remains a challenge for orthopaedic surgeons. Previous studies have demonstrated that pedicle screw fixation is highly correlated to the bone mineral density [1], and increasing the screw’s pullout strength can be achieved using a variety of methods, these include the use of pedicle screws with various designs [2,3]. However, ...

2015
Yongsheng Chen Krishna Prasad Giri Christopher Jon Pearce

Removal of metal implants is a common procedure that is performed for a variety of indications. However, problems such as a buried screw head may occasionally arise and render hardware removal difficult or even impossible. The problem is further compounded when the initial screw was inserted percutaneously or via a minimally-invasive (MIS) technique. In the present paper, we introduce a novel, ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید