نتایج جستجو برای: classic and center pivot irrigation was 7.92 t/ha

تعداد نتایج: 16911109  

Journal: :چغندرقند 0
محمدرضا ملک زاده مربی پژوهشی مؤسسه تحقیقات گیاهپزشکی کشور

in order to improve the efficiency of irrigation systems and investigate their impact on the pest population levels, furrow and sprinkler irrigation systems were compared in sugar beet fields. in this study, three different fields were chosen and irrigated by one of the furrow, classic and center pivot irrigation systems.  in each field, 20 plots were randomly selected of which 10 plots were ma...

Journal: :تحقیقات مهندسی کشاورزی 0
علی اصغر قائمی استادیار بخش آبیاری دانشکده کشاورزی دانشگاه شیراز

center pivot irrigation system is used as a modern irrigation method in different parts of iran. unfortunately due to lack of proper design and hydraulic shortcomings of the system in several agricultural lands in iran, the efficiency of the center pivot irrigation system is low or unacceptable. low system efficiency results in non-uniformity of water distribution along the lateral and on the c...

2014

27 28 The simulation of center-pivot performance has been the subject of research 29 efforts since the 1960s. Center-pivot models frequently use empirical equations 30 relating pressure and sprinkler radial application pattern. Individual, stationary 31 water application patterns are overlapped and the resulting water application is 32 mapped in the field. Such models use constant tower angular...

Use of the double ring infiltrometer to measure soil water infiltration in center pivot irrigation systems isn’t an accurate approach because the real conditions of infiltration under center pivot sprinklers is different from what happens in the double ring. In this study the infiltration parameters were evaluated in real conditions of a center pivot system. For this purpose a single ring...

2011
John Tooker

Excessive, wasted water has prompted the creation of the Top 10 Water Challenges of Nebraska [1]. 70% of the world’s water usage is related to agriculture [7], more efficient irrigation solutions promise a large benefit for farmers, consumers and the environment. Through a USGS grant, the Cyber-Physical Networking Lab at the University of Nebraska-Lincoln has pledged to complete an autonomous i...

2002
Wallace Wilhelm L. N. Mielke J. R. Gilley W. W. Wilhelm

reduce the amount of water used, resulting in savings Low-pressure sprinkler irrigation systems have the potential to of both water and energy. save energy, but also may aggravate soiland water-management Center-pivot systems with high pressure nozzles reproblems. The objective of this research was to determine the influquire relatively large amounts of energy to develop ence of center-pivot sp...

Journal: :نشریه علمی - پژوهشی هیدرولوژی کاربردی 0
amin rostami sari university ali a. sadraddini tabriz university amir h. nazemi tabriz university reza delir hasannia tabriz university

use of the double ring infiltrometer to measure soil water infiltration in center pivot irrigation systems isn’t an accurate approach because the real conditions of infiltration under center pivot sprinklers is different from what happens in the double ring. in this study the infiltration parameters were evaluated in real conditions of a center pivot system. for this purpose a single ring with ...

Journal: :journal of agricultural science and technology 2014
h. m. al-ghobari

system evaluations were performed on 48 center pivots in different parts of saudi arabia. these systems, located on different farms in four different regions of the country, namely: riyadh, jouf, qassim and eastern regions, were evaluated to study the effect of lateral configuration on water application uniformity as regards the original vs. modified laterals. lateral configuration modification...

Journal: :پژوهش آب در کشاورزی 0
امین رستمی دانشجوی سابق کارشناسی ارشد، گروه مهندسی آب، دانشگاه تبریز، ایران. علی اشرف صدرالدینی استاد گروه مهندسی آب، دانشگاه تبریز، ایران. امیرحسین ناظمی استاد گروه مهندسی آب، دانشگاه تبریز،ایران رضا دلیر حسن نیا استادیار گروه مهندسی آب، دانشگاه تبریز، ایران احمد فاخری فرد استاد گروه مهندسی آب، دانشگاه تبریز، ایران

use of the double ring infiltrometer to measure soil water infiltration in center pivot irrigation systems is not an accurate approach; because the real conditions of infiltration under center pivot sprinklers is different from what happens in the double ring. in this study, the infiltration parameters were determined under real conditions of a center pivot system. for this purpose, a single ri...

ژورنال: علوم آب و خاک 2005
علی اصغر قائمی, , فرید فروغی, ,

In irrigation scheduling, one question is “how much is the optimal depth?”. In this study the optimal irrigation depth (by assuming the power distribution function and by taking into consideration the distribution function, which governs the data (normal distribution)) by considering the environmental effects was determined for three water management strategies (i. e. unlimited, limited nitroge...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید