نتایج جستجو برای: concrete shear walls

تعداد نتایج: 179951  

Journal: :Journal of Structural and Construction Engineering (Transactions of AIJ) 1988

Journal: :مهندسی عمران مدرس 0
محمدرضا بمانیان محمد رضا اخوت هانیه اخوت

abstract: appealing to the principle of vertical residence and stemming the horizontal expansion of the city, the tehran milad tower is being built on 35000 sm3 site with the total area of 220000 sm3. with a height of over 170m, this 56-story concrete building is in the final stages of construction and would be the highest residential building of iran. since tehran is located in a high-risk ear...

The addition of steel fibers into concrete improves the postcracking tensile strength of hardened concrete and hence significantly enhances the shear strength of reinforced concrete reinforced concrete beams. However, developing an accurate model for predicting the shear strength of steel fiber reinforced concrete (SFRC) beams is a challenging task as there are several parameters such as the co...

2010
David I. McLean

By Timothy Phillips Vaughan, MS. Washington State University May 2010 Chair: David I. McLean This research evaluated the structural performance of reinforced masonry shear walls conforming to requirements given in the 2008 MSJC Building Code Requirements for Masonry Structures under cyclic lateral loading. Seismic design provisions in the 2008 MSJC provide prescriptive requirements for three di...

2016
Hongyu Deng Baitao Sun

During the analysis of reinforced concrete structures, the infill wall is usually simplified as a diagonal inclined strut to facilitate finite element modeling calculations. However, the actual seismic damage and single frame-filled wall pushover experimental results show that when the earthquake shear force is huge, the top of the infill wall and the beam–column connections are usually, thus t...

Journal: :Applied sciences 2022

Six RC short-limb shear walls with an L-shaped section, constructed high-strength rebar and concrete, were loaded to destruction pseudo-static loading. Experimental results discussed compared horizontal in detail. Different failure modes obtained, such as flexure-dominated for specimens aspect ratio of 2.8 2.15 bending-shear 1.75. With a decrease the ratio, ductility decreased, whereas increase...

2014
Matthew J. FOX Timothy J. SULLIVAN Katrin BEYER

In the seismic design of structures, capacity design is typically employed to ensure that a desirable ductile response is obtained. In this paper three different capacity design approaches for reinforced concrete coupled walls are investigated. For a simple case study building, the expected capacity design shear forces and bending moments are calculated using the different approaches. The resul...

Journal: :مهندسی سازه 0
میرحسن موسوی اصل

buildings with wall or frame-wall systems are more effective against earthquake forces and sustain less damage than buildings which their lateral resistance is solely depends on frames. four reinforced concrete (rc) structural wall specimens were subjected to cyclic loading using finite elements method with abaqus software in order to study influence of diagonal web reinforcement. the research ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید