نتایج جستجو برای: ctdi measurement

تعداد نتایج: 441251  

2010
Åsa Palm Elisabeth Nilsson Lars Herrnsdorf

According to published data, the absorbed dose used for a CBCT image acquisition with Varian OBI v1.3 can be as high as 100 mGy. In 2008 Varian released a new OBI version (v1.4), which promised to reduce the imaging dose. In this study, absorbed doses used for CBCT image acquisitions with the default irradiation techniques of Varian OBI v1.3 and v1.4 are measured. TLDs are used to derive dose d...

2014
Kihong Son Seungryong Cho Jin Sung Kim Youngyih Han Sang Gyu Ju Doo Ho Choi

Image-guided techniques for radiation therapy have improved the precision of radiation delivery by sparing normal tissues. Cone-beam computed tomography (CBCT) has emerged as a key technique for patient positioning and target localization in radiotherapy. Here, we investigated the imaging radiation dose delivered to radiosensitive organs of a patient during CBCT scan. The 4D extended cardiac-to...

Journal: :Journal of Biomedical Science and Engineering 2020

Journal: :Brazilian Journal of Radiation Sciences 2016

Journal: :Iranian Journal of Radiology 2023

Background: In the past several years, emerging imaging techniques, such as computed tomography angiography (CTA), Doppler ultrasound, and magnetic resonance (MRI), have been used for investigating anatomy perfusion of perforator complexes. Preoperative CTA can provide explicit information on flaps, which not only helps surgeons to evaluate optimal design flaps with respect lateral circumflex f...

Journal: :Journal of the South African Veterinary Association 2013
Nicolette Cassel Ann Carstens Pieter Becker

Computed tomography thoracic angiography studies were performed on five adult beagles using the bolus tracking (BT) technique and the test bolus (TB) technique, which were performed at least two weeks apart. For the BT technique, 2 mL/kg of 300 mgI/mL iodinated contrast agent was injected intravenously. Scans were initiated when the contrast in the aorta reached 150 Hounsfield units (HU). For t...

2004
P C Shrimpton

This report summarises work undertaken in support of a European Commission (EC) Concerted Action on CT that has included both a review and further development of the framework for CT dosimetry. The system previously established by the EC for reference doses in CT (with the quantities weighted CTDI (CTDIw) and dose-length product (DLP)) has been expanded to include subsequent developments in CT ...

2017
Stephanie Leon

Mobile fluoroscopy (c-arm) units offering 3D image reconstruction are becoming more common in surgical settings. Although these images are "CT-like" and sometimes replace the postoperative CT, the acquisition is technically very different from a traditional CT acquisition. Dose assessment is complicated by a large beam width, automatic exposure rate control, and a rotation of less than 360°. Th...

Journal: :AJR. American journal of roentgenology 2015
Samuel L Brady Amy E Mirro Bria M Moore Robert A Kaufman

OBJECTIVE The purpose of this study is to show how to calculate effective dose in CT using size-specific dose estimates and to correct the current method using dose-length product (DLP). MATERIALS AND METHODS Data were analyzed from 352 chest and 241 abdominopelvic CT images. Size-specific dose estimate was used as a surrogate for organ dose in the chest and abdominopelvic regions. Organ dose...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید