نتایج جستجو برای: dbm تجاری

تعداد نتایج: 19528  

2006
Shaikh K. Alam Joanne DeGroat

This paper describes a 1.5-V 5 GHz I/Q down conversion mixer in a 0.18-μm CMOS process. The mixer achieves a conversion gain of 12.7 dB within 1-dB compression point (iCP1dB) of -15.83 dBm. It also achieves a double side band (DSB) NF of 13.5 dB. The mixer's IIP3 is -5.94 dBm. The mixer consumes only 5.72 mA of current from a 1.5-V power supply. Key-Words: Analog RF-CMOS, IEEE 802.11a, IEEE 802...

Journal: :iranian journal of basic medical sciences 0
zahra sadat hashemi department of medical biotechnology, faculty of medical sciences, tarbiat modares university, tehran, iran mahdi forouzandeh moghadam department of medical biotechnology, faculty of medical sciences, tarbiat modares university, tehran, iran masoud soleimani department of hematology, faculty of medical sciences, tarbiat modares university, tehran, iran

objective(s): ex vivo expansion of hematopoitic stem cells is an alternative way to increase umbilical cord blood (ucb)-cd34+ cells for bone marrow transplantation. for this purpose demineralized bone matrix (dbm) and mineralized bone allograft (mba) as two scaffolds based on bone matrix and stem cell niche, were simultaneously used to enhance the effect of human mesenchymal progenitor cells (m...

1998
Enrico Rubiola Vincent Giordano Jacques Groslambert

The interferometric technique allows close-to-the-carrier measurements of both phase and amplitude noise, improving the instrument noise floor by 10–25 dB as compared to the traditional method based on a saturated mixer. Principles and basic equations describing the noise measurement system are given, together with design strategies suitable to microwave and very high frequency bands. Two proto...

2013
Lisa J White Stephen F Badylak Kevin M Shakesheff

The extracellular matrix (ECM) of mammalian tissues has been isolated, decellularized and utilized as a scaffold to facilitate the repair and reconstruction of numerous tissues. Recent studies have suggested that superior function and complex tissue formation occurred when ECM scaffolds were derived from site specific homologous tissues compared to heterologous tissues. Musculoskeletal conditio...

2013
Murat CELEP Şenel YARAN Cem HAYIRLI Handan SAKARYA

Abstrac t An interlaboratory comparison of microwave power measurement (project UME-EM-10-02) was carried out among eight (8) laboratories in Turkey. In this comparison, it was requested to make microwave power measurements at +10 dBm, 0 dBm and -15 dBm power levels with 0.03 GHz, 1 GHz, 7 GHz, 12 GHz and 18 GHz frequencies with their own measurement systems and methods. The measurement results...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تبریز 1390

lna که به صورت دو– بهره ای طراحی شده است ، دارای گین های db 39.4و db 0.5- بوده و nf آن db 0.7 و دارای تطبیق امپدانسی بسیار خوب با s_11=-34db می باشد . میکسرهای غیر فعال بدون استفاده از بافرهای lo طراحی شده اند ،که خو د به میزان بسیار زیادی موجب صرفه جوئی در مصرف توان شده ، و در عین حال عملکرد آنها از بسیاری از میکسرهای راه اندازی شده با بافر هم بهتر است . iip3 این میکسر dbm 14.4 و p1db آن dbm 5...

2014
Antwi Nimo Dario Grgić Leonhard M. Reindl

This work presents the optimization of radio frequency (RF) to direct current (DC) circuits using Schottky diodes for remote wireless energy harvesting applications. Since different applications require different wireless RF to DC circuits, RF harvesters are presented for different applications. Analytical parameters influencing the sensitivity and efficiency of the circuits are presented. Resu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید