This contribution investigates to what extent the current grid can cope with area-wide deployment of electrical vehicles and renewable energies. It is also investigated at what point additional measures, such as grid reinforcement or load management systems (LMS) are necessary for stable operation. Simulations where conducted with the power grid calculation software DIgSILENT PowerFactory. Diff...
This paper reviews different approaches for unbalanced load flow analysis within a distribution network, especially in a microgrid (MG). Models of untransposed distribution lines and unbalanced loads are considered for each methodology, as these are common in a MG scenario. Various commercial software packages are also investigated and assessed in terms of solving the power flow of the MGs and ...
Future energy demand and increasing carbon emission requires an alternative source of energy. In recent few years, Use of DFIG based wind farm increased tremendously, thus effect of wind penetration on small signal stability of existing multi machine system need to be analysed. In This paper effect of penetration of wind turbine with DFIG on stability performance of the IEEE 9 bus and 39 bus sy...
reliability evaluation of a large-scale composite power system faces to numerous events/outage and consequently imposes an extensive burden of calculations. in order to simplify the problem, determination of an equivalent system for large-scale power system is inevitable. this paper proposes a framework as reduction technique to separate a composite power system to three areas: external area, o...
superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...
In islanding, a portion of the power network, comprised of the loads and distributed generation (DG) units, is isolated from the rest of the power grid and forms a micro grid (MG). In this condition, it becomes essential for the islanded MG to operate in a stable and controlled manner by providing ancillary services. When the MG is cut off from the main grid, the islanding must be detected by t...
Present-day small hydropower plants (SHPs) have a large development potential because of the increasing interest in renewable resources and distributed energy generation, therefore, there are many SHPs in places of China where are rich in water resources. However, it has caused overvoltages in the distribution network, and which is even worse for the switching overvoltage such as isolated netwo...