نتایج جستجو برای: dose distribution verification

تعداد نتایج: 975918  

2010
Cheng-Shie Wuu

Both polymer gels and PRESAGE radiochromic solid dosimeter, in conjunction with optical CT scanning system, have been employed to measure 3-D dose distribution. The 3-D dose maps obtained from these systems can provide a useful tool for dose verification on complex treatments such as IMRT, radiosurgery, and RapidArc. These complex treatments present high dose gradient regions in the boundaries ...

Journal: :Medical physics 1999
K L Pasma M L Dirkx M Kroonwijk A G Visser B J Heijmen

Dose distributions can often be significantly improved by modulating the two-dimensional intensity profile of the individual x-ray beams. One technique for delivering intensity modulated beams is dynamic multileaf collimation (DMLC). However, DMLC is complex and requires extensive quality assurance. In this paper a new method is presented for a pretreatment dosimetric verification of these inte...

2016
Laurence Autret Julien Bert Yannick Lemaréchal Laurent Desbat Dimitris Visvikis

The verification of the dose delivered to a patient during radiation therapy is a particularly important step for ensuring treatment quality. This step, known as in vivo dosimetry can be realized using a bidimensional dosimeter named Electronic Portal Imaging Device (EPID). However, few methods enable the determination of an accurate and fully personalized 3D dose distribution for the most curr...

Journal: :iranian journal of medical physics 0
reza faghihi assistant professor, medical radiation department and radiation research center, school of engineering, shiraz university, shiraz, iran mohammad amin mosleh-shirazi assistant professor, radiotherapy department and center for research in medical physics and biomedical engineering, shiraz university of medical sciences, shiraz, iran fatemeh moradi-mocarram m.sc. in medical radiation, school of engineering, shiraz university, shiraz, iran

introduction: the selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. material and methods: in this work, an efficient method is presented within the matlab environment to investigate how to improv...

Journal: :IOP conference series 2021

Abstract Since its discovery in 1946, Proton therapy has continued to overgrow from the number of units installed various countries and technology used. This paper aims provide an overview development proton facilities date based on a literature review. The results are discussed several aspects, including distribution across globe, beam delivery techniques, dose verification, room layout, shiel...

2017
Keita Kurosu Iori Sumida Hiroya Shiomi Hirokazu Mizuno Hiroko Yamaguchi Hirofumi Okubo Keisuke Tamari Yuji Seo Osamu Suzuki Seiichi Ota Shinichi Inoue Kazuhiko Ogawa

In this CyberKnife® dose verification study, we investigated the effectiveness of the novel potential error (PE) concept when applied to the determination of a robust measurement point for targeting errors. PE was calculated by dividing the differences between the maximum increases and decreases in dose distributions by the original distribution after obtaining the former by shifting the source...

Journal: :Medical physics 2006
Markus Wendling Robert J W Louwe Leah N McDermott Jan-Jakob Sonke Marcel van Herk Ben J Mijnheer

The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous silicon EPID. By using this back-projection algorithm, two-dimensional dose distr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید