Hadi Keivan Mohammad Ali Behrooz Mohammad Javad Tahmasebi Birgani,

Introduction: Treatment with megavoltage electron beams is ideal for irradiating superficial tumors because of their limited range in tissues. However, for electron treatment of extended areas, such as the chest wall, two or more adjacent fields can be used. Abutment of these fields may lead to significant dose in homogeneities in the junction region. The aim of this study is to offer a new met...

Journal: :journal of biomedical physics and engineering 0
m robatjazi tehran university of medical sciences k tanha bushehr university of medical sciences s r mahdavi iran university of medical sciences h r baghani shahid beheshti university h r mirzaei shahid beheshti university of medical sciences m mousavi tehran university of medical sciences

background: one of the main problems of dedicated iort accelerators is to determine dosimetric characteristics of the electron beams. monte carlo simulation of iort accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry. materials and methods: liac accelerator head was modeled using the beamnrcmonte carlo simulation system. phase-space files were generated a...

آقامیری, سید محمود رضا, باغانی, حمیدرضا, حیدرلو, نعمت‌الله, مهدوی, سید ربیع,

Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...

Journal: :علوم و تکنولوژی پلیمر 0
آرزو مشاک سیدمجتبی تقی زاده

modification of the mechanical properties of silicone rubber were considered for drug delivery systems by using high-energy electron beam (e-beam). in this research work, two different medical grades of silicone rubbers were used to prepare matrices containing 10wt% progesterone with 2 mm thickness and irradiated with e-beam at dose range of 25 up to 200 kgy. then, the mechanical properties as ...

Journal: :jentashapir journal of health research 0
mohammad javad tahmasebi birgani department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran mansour zabihzadeh department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; student research committee, ahvaz jundishapur university of medical sciences, ahvaz, ir lran; department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran. tel: +98-9125032283 sholeh arvandi department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran elahe gharibreza department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran

conclusions using the maximum dose depth from pdd curves and the inverse square law, the required ssdeff to calculate the dose distribution of the electron beam can be calculated. objectives the aim of this study was to determine the effective source-surface distance (ssdeff) of an electron linear accelerator (linac), and its dependence on energy and depth. materials and methods a varian linac ...

Journal: :iranian journal of science and technology (sciences) 2008
a. akhavan

in order to improve the performance of a newly developed radiochromic film, gic-79, somedosimetric characteristics of this film have been studied based on relevant standard practice. the presentstudy describes some parameters that may affect the dosimeter response before, during, and after irradiation. the effect of absorbed dose rate on dosimeter response was determined by irradiating dosimete...

Nanostructured TiO2-SnO2 thin-film ethanol sensors have been fabricated on glass substrates using electron beam and sol-gel methods. The surface structure, morphology and optical transmission characteristics of the films were analyzed by X ray diffraction, scanning electron microscopy and UV/VIS/NIR spectrometry. The TiO2-SnO2 films were less than 300 nm thick and consisted of nanocrystallines ...

Journal: :iranian journal of applied animal science 2015
f. ghanbari t. ghoorchi p. shawrang h. mansouri n.m. torbati-nejad

this research was performed to compare electron beam (eb) and gamma ray (gr) treatments at doses of 25, 50 and 75 kilo gray (kgy) on ruminal degradation kinetics and in vitro digestibility of sunflower meal (sfm). ionizing radiations of eb and gr had significant effects )p

Journal: :veterinary research forum 2015
masoud moradi ahmad afzalzadeh mehdi behgar mohammad ali norouzian

the current study evaluated the effects of electron beam (eb; 10, 20, 30 and 40 kgy), urea and naoh treatments on chemical composition, phenolic compounds, in vitro gas production and in situ ruminal degradability of pistachio by-product (pb). the eb decreased (p < 0.01) neutral detergent fiber (ndf), acid detergent fiber (adf) and acid detergent lignin (adl) contents of pb. treating pb by naoh...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تهران 1386

چکیده ندارد.