نتایج جستجو برای: electrostatic force

تعداد نتایج: 210368  

Journal: :journal of optoelectronical nano structures 0
mohammad ghalambaz department of mechanical engineering, dezful branch, islamic azad university, dezful, iran.c research center. ali j chamkha mechanical engineering department, prince mohammad bin fahd university (pmu) p.o. box 1664 al-khobar 31952, kingdom of saudi arabia mehdi ghalambaz department of mechanical engineering, dezful branch, islamic azad university, dezful, iran.c research center. mohammad edalatifar department of electrical engineering, dezful branch, islamic azad university, dezful, iran.

the natural frequency and pull-in instability of clamped-clamped nano-actuators in the presence of a dielectric layer are analyzed. the influence of the presence of casimir force, electrostatic force, fringing field effect, axial force, stretching effects and the size effect are taken into account. the governing equation of the dynamic response of the actuator is transformed in a non-dimensiona...

2011
Ali Shokuhfar Payam Heydari Salman Ebrahimi-Nejad

This paper describes an electrostatic excited microcantilever sensor operating in static mode that is more sensitive than traditional microcantilevers. The proposed sensor comprises a simple microcantilever with electrostatic excitation ability and an optical or piezoresistive detector. Initially the microcantilever is excited by electrostatic force to near pull-in voltage. The nonlinear behavi...

Journal: :international journal of environmental research 2012
s.r. singh a.p. singh

presence of heavy metals in the aquatic systems has become a serious problem. as a result, therehas been a great deal of attention given to new technologies for removal of heavy metal ions from contaminated waters. adsorption is one of the effective methods for removal of toxic heavy metal such as chromium (vi). in the present study, adsorbent is prepared from rice husk, a low cost by product f...

Journal: :international journal of environmental research 0
s.r. singh house number 27, deep nagar colony, near transport nagar, agra, uttar pradesh, india a.p. singh faculty of engineering and technology, r.b.s. college, bichpuri, agra, uttar pradesh, india

presence of heavy metals in the aquatic systems has become a serious problem. as a result, therehas been a great deal of attention given to new technologies for removal of heavy metal ions from contaminated waters. adsorption is one of the effective methods for removal of toxic heavy metal such as chromium (vi). in the present study, adsorbent is prepared from rice husk, a low cost by product f...

G. Rezaei Behbehani

Effects of ?-cyclodextrin, ?CD, on refolding of lysozyme was investigated at pH 12 employing isothermal titration calorimetry (ITC) at 300K in 30mM Tris buffer solution. ?CD was employed as an anti-aggregation agent and the heats obtained for lysozyme+?CD interactions are reported and analyzed in terms of the extended solvation model. It was indicated that there are two sets of identical and no...

Journal: :Proceedings of the National Academy of Sciences of the United States of America 1995
S Xu M F Arnsdorf

A scanning force microscope was converted to an electrostatic force microscope by charging the usually neutral cantilever with phospholipids. The electrostatic force microscope was used to study surface electrostatic charges of samples in aqueous solutions. Lysozymes, DEAE-Sephadex beads, 3-propyltriethoxysilane-treated glass and mica were imaged in water or phosphate buffer with electrostatic ...

2014
Megat Muhammad Ikhsan Megat Hasnan Mohd Faizul Mohd Sabri Suhana Mohd Said Nik Nazri Nik Ghazali

This paper presents the design and evaluation of a high force density fishbone shaped electrostatic comb drive actuator. This comb drive actuator has a branched structure similar to a fishbone, which is intended to increase the capacitance of the electrodes and hence increase the electrostatic actuation force. Two-dimensional finite element analysis was used to simulate the motion of the fishbo...

2015
Byung I. Kim

Magnetic force microscopy (MFM) using electrostatic force modulation has been designed and developed to avoid the drawbacks of the bimorph driven system. The bimorph driven system has poor frequency response and overlap of the topographic features on magnetic structures of the MFM images. In the electrostatic force modulation system, the amplitude increases in the noncontact regime as the tip a...

Journal: :Chemical & pharmaceutical bulletin 2002
Satoru Watano Tomohiro Hamashita Teruo Suzuki

A novel fine particle removal system composed of a corona-discharge neutralizer, a pulse-jet air unit and an image processing system has been developed. First of all, adhesion force between particle and film was directly measured and effect of electrostatic force on the adhesion force was calculated experimentally and theoretically. The electrostatic force was found to be significant, leading t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید